B. SAFETY CONSIDERATIONS ... .5 2. Product Description The 135 is a hand held manual ranging DMM. It features C. TECHNICAL DATA extra large numerals on the LCD, and Data Hold for all Features and Benefits .
1992 Immunity Standard ALWAYS EN61010-1 1993 Safety Standard • Test the 135 before using it to make sure it is EN61010-2-031 1995 Safety Standard operating properly. To ensure conformity with these standards, this instrument • Inspect the test leads before using to make sure must be operated in accordance with the instructions and there are no breaks or shorts.
INTERNATIONAL SYMBOLS 2. Product Applications CAUTION: RISK OF ELECTRIC SHOCK Perform the following tests and/or measurements with the TPI 135 and the appropriate function: AC (ALTERNATING CURRENT) HVAC/R DC (DIRECT CURRENT) FUNCTION REFER TO INSTRUCTION MANUAL DCmV • Thermocouples in furnaces or gas GROUND applications.
Plug red test lead into VΩ input jack. Set the rotary switch on the 135 to the desired range Used for measurement of Resistance, Diode Test in the DCV function depending on the voltage to be and Continuity Buzzer.
3. Plug red test lead into VΩ input jack. personal injury may result. 4. Set the rotary switch on the 135 to the desired range WARNING! in the ACV function depending on the voltage to be Do not attempt to make a voltage measurement of more than measured.
Page 8
Plug red test lead into mAµA or A input jack the circuit. depending on value of current to be measured. Set the rotary switch on the 135 to the desired range WARNING! in the DCA function depending on the current to be...
• Connect the red test lead to one power Set the rotary switch on the 135 to the desired range input line of the motor and the black in the OHM function depending on the voltage to be test lead to the other power input line measured.
Plug black test lead into the COM input jack. Plug the red test lead into the VΩ input jack. Set the rotary switch on the 135 to the position. Connect the black test lead to the banded end of the Set the rotary switch to the function.
Plug the black test lead into the COM input jack. Temperature Adapter A301 Plug the red test lead into the V input jack. Set the rotary switch on the 135 to the position. Boot Hook A103 Connect the test leads to the circuit to be measured.
Reassemble instrument in reverse order from above. All functions except ohms read high Fuse Replacement: Both of the 135 “A” and “mAµA • Very weak battery that will input jacks are fuse protected. Use only Fast Blow, not turn on the low battery 600 Volt fuses with correct current ratings.