4. O
PERATION
Control Panel Operation
Button
Function
<MENU> Exits from the current menu or function
<ENTER> Enables the currently displayed menu or sets the currently selected value in to the current
function
<UP>
Navigates upward through the menu list or increases the numeric value when in a function
<DOWN> Navigates downward through the menu list or decreases the numeric value when in a function
Programming
Refer to the Menu Map to understand the menu options. The menu map shows the main level and a
variable number of programming levels for each option.
•
To go to the desired main level, press <MENU> repeatedly until the option shows on the display.
Press <ENTER> to select. This will take you to the first programming level for that option.
•
To select an option or value within the current programming level, press <UP> or <DOWN> until
the option shows on the display. Press <ENTER> to select. In this case, if there is another
programming level, you will see that first option, or you will see the selected value.
•
Press <MENU> repeatedly to exit to the previous main level.Ovation B-1965FC
Menu Map
Main Level
Protocol
Start
Address
Personality
Page 8 of 35
Programming Levels
DMX512
ArtNet
sACN
001–512*
DMX-VCW-CCT
RGB 3CH
RGBA 4CH
RGBAL 5CH
RGB EXT 8CH
RGBA EXT 9CH 9-channel: 16-bit dimmer, RGBA, virtual
1 Cell
RGBAL EXT
10CH
RGBAL Fine
10CH
RGBAL FULL
Description
Selects the control protocol
Selects starting address (*highest channel
restricted by selected personality)
3-channel: dimmer, virtual color wheel,
3CH
color temperature
3-channel: RGB
4-channel: RGBA
5-channel: RGBAL
8-channel: 16-bit dimmer, RGB, virtual
color wheel, color temperature, strobe
color wheel, color temperature, strobe
10-channel: 16-bit dimmer, RGBAL, virtual
color wheel, color temperature, strobe
10-channel: 16-bit RGBAL
17-channel: 16-bit dimmer, 16-bit RGBAL,
virtual color wheel, color temperature,
17CH
strobe, color macros, dimmer mode
Ovation B-1965FC User Manual Rev. 1
O
PERATION