BMW i wallbox connect Installation Instructions Manual page 36

Table of Contents

Advertisement

Terminal data:
Category
Rigid cable
Cat 5e/Cat 6 STP/UTP
Cat 6 STP/UTP
Flexible cable
Cat 5e/Cat 6 STP/UTP
Recommended tool:
KRONE LSA+ ® insertion tool, for connecting wires without the use of solder, screws, or stripping, and
for simultaneous trimming of the residual length.
ATTENTION
Risk of damage!
Ensure that the connection area is clean, so that no contamination, e.g. pieces of wire, gets into
the Wallbox. 
36
Wire diameter
14.17 mils (AWG 27)
14.75 – 25.20 mils
(AWG 26 – AWG 22)
20.08 – 31.89 mils
(AWG 24 – AWG 20)
7 x 0.2 mm
(AWG 24)
Preparing the connection cable
1. Strip the connection cable to a length of
approx. 2.36 inches.
2. Completely fold back approx. 0.39 inches of
screening braid, and wind conductive textile
adhesive tape around it.
Connecting the cable
1. If using an STP cable, attach the connection
cable to the location of the wrapped screening
braid in the cable clip 1.
The cable clip must be screwed to the shield
connection Shd of the circuit board.
2. Connect the wires to the Ethernet1 terminal
block X4 using the insertion tool.
Insulation diameter
27.56 – 29.53 mils
27.56 – 55.12 mils
39.37 – 55.12 mils
43.31 – 55.12 mils

Hide quick links: