Operation; Preparations At The Workplace; Fitting The Accessory Tool - Hilti TE 2000-AVR Operating Instructions Manual

Table of Contents

Advertisement

accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This may significantly reduce exposure over the
total working period. Identify additional safety measures to protect the operator from the effects of noise
and/or vibration, for example: maintenance of the electric tool and the accessories, keeping the hands warm,
organization of work patterns.
Noise emission values
Measured sound power level (L
Guaranteed sound power level (L
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Vibration values
Chiseling (a
)
h, Cheq
Uncertainty (K)

5 Operation

5.1 Preparations at the workplace

CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing
accessories.
Observe the safety instructions and warnings in this documentation and on the product.

5.1.1 Fitting the accessory tool

1. Unplug the supply cord from the power outlet.
2. Lightly grease the connection end of the accessory tool.
◁ Use only the recommended grease supplied by Hilti. Using the wrong grease can result in damage
to the tool.
3. Push the accessory tool into the chuck as far as it will go, turning it and applying light pressure until it
engages with an audible click.
4. Check that the chisel has engaged correctly by gripping and pulling it.
Printed: 17.02.2017 | Doc-Nr: PUB / 5333067 / 000 / 00
)
WA
)
WAd
)
WA
)
pA
)
pA
97 dB(A)
100 dB(A)
3 dB(A)
77 dB(A)
3 dB(A)
3.8 m/s²
1.5 m/s²