Installation; Technical Specifications; Safety Precautions; Select Suitable Location - Lincoln Electric POWER MIG180 DUAL Operator's Manual

Hide thumbs Also See for POWER MIG180 DUAL:
Table of Contents

Advertisement

Available languages

Available languages

POWER MIG
180 DUAL
®
TECHNICAL SPECIFICATIONS 180 Amp unit (K3018-1)
INPUT – SINGLE PHASE ONLY
Standard Voltage/Frequency
230 V
60 Hz
208 V
60 Hz
120 V
60 Hz
Voltage/Duty Cycle
230 V
30%
208 V
30%
120 V
20%
Welding Current Range
(208 V / 230 V) 30-180 Amps
(120 V)
30-140 Amps
RECOMMENDED INPUT CABLE AND FUSE SIZES
Input Voltage / Frequence
230 V / 208 V 60 Hz
120 V
60 Hz
PHYSICAL DIMENSIONS
Height
Width
14.08 in.
10.37 in.
357.6 mm
263.4 mm
1
If connected to a circuit protected by fuses use Time Delay Fuse marked "D".
2
Requirements for maximum output: In order to utilize the maximum output capability of the machine, a branch circuit capable of 30 amps
@ 120 volts, 60Hz is required.
Read entire installation section before starting

installation.

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.
• Only qualified personnel should perform
this installation.
• Only personnel that have read and
understood the POWER MIG
Operating Manual should install and
operate this equipment.
• Machine must be plugged into a recep-
tacle which is grounded per any nation-
al, local or other applicable electrical
codes.
• The POWER MIG
switch is to be in the OFF ("O") position
when installing work cable and gun and
when connecting power cord to input
power.
------------------------------------------------
Input Current
20 Amps @ rated output
RATED OUTPUT
Current
Voltage at Rated Amperes
130 Amps
130 Amps
90 Amps
OUTPUT
Open Circuit Voltage
34 V
33 V
Fuse or Breaker Size
1
Input Amps
40 Amp
20 Amp
2
Depth
Weight
18.78 in.
66 lbs.
477.6 mm
30 kg.
WARNING
180 DUAL
®
180 DUAL power
®
20
17.6
19.5
Wire Speed Range
50 - 500 in/min.
(1.3 - 12.7 m/min.)
(Power Cord) Lincoln Electric Part Number
20
M22590
20
M22589

SELECT SUITABLE LOCATION

Locate the POWER MIG
is free circulation of clean air into the louvers in the back and out
the front of the unit. A location that minimizes the amount of
smoke and dirt drawn into the rear louvers reduces the chance
of dirt accumulation that can block air passages and cause over-
heating.

STACKING

POWER MIG
180 DUAL cannot be stacked.
®

TILTING

Each machine must be placed on a secure, level surface, directly
or on recommended cart. The machine may topple over if this
procedure is not followed.
A 1
INSTALLATION
180 DUAL in a dry location where there
®

Advertisement

Table of Contents
loading

This manual is also suitable for:

11828Power mig 180 dual

Table of Contents