Power Switch - Henny Penny HHC-902 Technical Manual

Heated holding cabinet
Hide thumbs Also See for HHC-902:
Table of Contents

Advertisement

2-7. POWER SWITCH

2-4
1. Disconnect the electrical supply to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the four (4) screws from the control panel and pull it
Step 3
down.
3. Remove all wires from the switch. Check across the two
terminals of the switch for continuity. With the switch in the
ON position, the circuit should be closed. With the switch in
the OFF position, the circuit should be open. If the switch is
found to be defective, replace it by continuing with the fol-
lowing instructions in this section.
4. Loosen the nut holding the switch on the back side of the con-
trol panel and then remove the nut on the front of the control
panel.
5. Remove the switch.
Step 4
6. Install a new switch in reverse order.
7. Reconnect the wires to the switch on the same terminals that
they were previously on.
8. Push the control panel back in place and put in screws.
9. Reconnect the electrical supply to the cabinet.
Models HHC-90X/HC-15
803

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hhc-900Hhc-908Hhc-906Hhc-903Hc-15

Table of Contents