Do you have a question about the 90-01 and is the answer not in the manual?
Questions and answers
surjit Birk
May 21, 2025
where is the noise data??? for CLA-VAL 90-01
TRACEY
May 16, 2025
I HAVE 90-01 2-1/2" VALVE
AND NEEDS A REPLACEMENT VALVE BUT WANTS IT SET AT 125#
WOULD THAT HAVE TO DO WITH SPRING RANGE SINCE WE USALLY
SUPPLY 30-300 ON VALVES
Page 4
OPTIONAL FEATURES Suffix (A) - Internal strainer self-cleaning: In some applications the self-cleaning strainer CLA-VAL, type X46A screwed at the inlet of main valve (1) reduces maintenance generated by the cleaning of the standard strainer screen (3). With this option (A) the strainer X46A replaces the strainer (3) and the orifice of the X44A strainer (3) is replaced by the orifice assembly X58-CSA.
Page 5
(cover chamber). The CLA-VAL 100-01 is the basic valve used in nearly in all CLA-VAL Automatic Control Valves. There are 3 HYTROL body types:...
Page 6
More Information Sheet # • Diagram to be used as a guide only. Quick Valve Selection 000121DE Sizing Software Run CLA-VAL Softwares To obtain a more accurate calculation please contact CLA-VAL CLA-VAL Europe www.cla-val.ch cla-val@cla-val.ch 1 - 000121DE E 11/08...
Page 7
(valve totally open). • Sizing Software Run CLA-VAL Softwares Minimum Opening Pressure: 0,2 [bar]. • Minimum Differential Pressure: 0,5 [bar]. For lower opening Pressure or differential pressure, please contact CLA-VAL CLA-VAL Europe www.cla-val.ch cla-val@cla-val.ch 2 - 000121DE E 11/08...
Page 10
4. Allow sufficient room around valve to make adjustments and for disassembly. 5. CLA-VAL 100-01 HYTROL Valves operate with maximum efficiency when mounted in horizontal piping with the cover UP, however, other positions are acceptable. Due to size and weight of the cover and internal components of 8 inch and larger valves, installation with the cover UP is advisable.
Page 11
(usually between inlet and discharge pressure. the diaphragm chamber the valve atmosphere) the line pressure With the use of a CLA-VAL. "modulating closes drip-tight. (5 psi Min.) at the valve inlet control," which reacts to line pressure opens the valve.
Page 12
5. For most valves it can be done after completing Diaphragm Check (Steps 1., 2., and 3.). SEE CAUTION!. At the end of step 3. the valve should be fully open. 6. If the valve has a CLA-VAL X101 Position Indicator, observe the indicator to see that the valve opens wide. Mark the point of maximum opening.
Page 13
MAINTENANCE PREVENTATIVE MAINTENANCE The CLA-VAL Model 100-01 HYTROL Valve requires no lubrication or packing and a minimum of maintenance. However, a periodic inspection schedule should be established to determine how the operating conditions of the system are affecting the valve. The effect of these actions must be determined by inspection.
Page 14
CLA-VAL 100-01 Installation - Operation - Maintenance NGE - GE - AE On 6” and smaller valves block and tackle or a power hoist can be used to lift valve cover by inserting proper size eye bolt in place of the center cover plug. On 8” and larger valves there are 4 holes (5/8” - 11 size) where jacking screws and/or eye bolts may be inserted for lifting purposes.
Page 15
CLA-VAL 100-01 Installation - Operation - Maintenance NGE - GE - AE INSPECTION OF PARTS After the valve has been disassembled, each part should be examined carefully for signs of wear, corrosion, or any other abnormal condition. Usually, it is a good idea to replace the rubber parts (diaphragm and disc) unless they are free of signs of wear.
Page 16
® CLA-VAL 100-01 NGE Vanne de base - Main Valve – Hauptventil Ecrou Mutter Rondelle Washer Scheibe Chapeau Cover Deckel Palier de chapeau Cover bearing Deckellager Ressort Spring Feder Ecrou d'axe Stem nut Stösselmutter NGE DN 500 - DN 600...
Page 17
CLA-VAL 100-01 NGE DN 50 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 40/PN 10 - 16 91698-04 CLA-KIT HYTROL100-01 - GE 40/PN 25 CLA-VAL POS.
Page 18
CLA-VAL 100-01 NGE DN 65 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 50/PN 10 - 16 91698-05 CLA-KIT HYTROL100-01 - GE 50/PN 25 CLA-VAL POS.
Page 19
CLA-VAL 100-01 NGE DN 80 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 50/PN 10 - 16 91698-05 CLA-KIT HYTROL100-01 - GE 50/PN 25 CLA-VAL POS.
Page 20
CLA-VAL 100-01 NGE DN 100 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 80/PN 10 - 16 91698-12 CLA-KIT HYTROL100-01 - GE 80/PN 25 CLA-VAL POS.
Page 21
CLA-VAL 100-01 NGE DN 125 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 100/PN 10 - 16 91698-13 CLA-KIT HYTROL100-01 - GE 100/PN 25 CLA-VAL POS.
Page 22
CLA-VAL 100-01 NGE DN 150 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 100/PN 10 - 16 91698-13 CLA-KIT HYTROL100-01 - GE 100/PN 25 CLA-VAL POS.
Page 23
CLA-VAL 100-01 NGE DN 200 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 150/PN 10 - 16 91698-15 CLA-KIT HYTROL100-01 - GE 150/PN 25 CLA-VAL POS.
Page 24
CLA-VAL 100-01 NGE DN 250 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 200/PN 10 - 16 91698-30 CLA-KIT HYTROL100-01 - GE 200/PN 25 CLA-VAL POS.
Page 25
CLA-VAL 100-01 NGE DN 300 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 250/PN 10 - 16 91698-31 CLA-KIT HYTROL100-01 - GE 250/PN 25 CLA-VAL POS.
Page 26
CLA-VAL 100-01 NGE DN 350 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 300/PN 10 - 16 91698-32 CLA-KIT HYTROL100-01 - GE 300/PN 25 CLA-VAL POS.
Page 27
CLA-VAL 100-01 NGE DN 400 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 300/PN 10 - 16 91698-32 CLA-KIT HYTROL100-01 - GE 300/PN 25 CLA-VAL POS.
Page 28
CLA-VAL 100-01 NGE DN 450 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 300/PN 10 - 16 91698-32 CLA-KIT HYTROL100-01 - GE 300/PN 25 CLA-VAL POS.
Page 29
CLA-VAL 100-01 NGE DN 500 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 400/PN 10 - 16 91698-34 CLA-KIT HYTROL100-01 - GE 400/PN 25 CLA-VAL POS.
Page 30
CLA-VAL 100-01 NGE DN 600 PN 10 - 16 - 25 STD: STANDARD PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT HYTROL100-01 - GE 400/PN 10 - 16 91698-34 CLA-KIT HYTROL100-01 - GE 400/PN 25 CLA-VAL POS.
Page 31
® CLA-VAL CRD Pilote - Control - Steuerventil PN 10 - 16 - 25 PILOTE DE REDUCTION DE PRESSION Le pilote de réduction de pression est du type normalement ouvert, à action indirecte. Une augmentation de la pression de sortie tend à fermer le pilote, au contraire une diminution de la pression de sortie tend à...
Page 32
CLA-VAL CRD Pilote - Control - Steuerventil PN 10 - 16 - 25 STD: Standard PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT CRD (0,1 - 0,5 / 0,1 - 2,1 bar)
Page 33
It may be used as a self- enter guide hole in plug as it is assembled. Screw the plug in contained valve or as a pilot control for a CLA-VAL main valve. by hand. Use wrench to tighten only.
Page 34
® CLA-VAL CV Robinet à pointeau - Flow Control Cock - Nadelventil PN 10 - 16 - 25 ROBINET A POINTEAU Note : Le robinet à pointeau à action unidirectionnelle permet de régler la vitesse d'ouverture de la vanne de base.
Page 35
CLA-VAL CV Robinet à pointeau - Flow Control Cock - Nadelventil PN 10 - 16 - 25 STD: Standard PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT CV Standard *CKCV-STD-01 POS.
Page 36
REPAIR AND REPLACEMENT Minor nicks and scratches may be polished out using a fine The CLA-VAL Model CV Flow Control is a simply- grade of emery or crocus cloth; replace parts if scratches designed, spring-loaded check valve. Rate of flow is full cannot be removed.
Page 37
® CLA-VAL X44-A Filtre - Strainer - Filter X44-A1 & X44-A3 PN 10 - 16 - 25 FILTRE A BUSE INCORPOREE Ce filtre empêche tout corps étranger d'entrer dans le circuit d'asservissement. Il est recommandé de nettoyer périodiquement la cartouche du filtre. La vitesse de réaction de la vanne est liée au diamètre de la buse.
Page 38
CLA-VAL X44-A Filtre - Strainer - Filter X44-A1 & X44-A3 PN 10 - 16 - 25 STD: Standard PIECE DE RECHANGE / SPARE PARTS / ERSATZTEILE KIT DE REPARATION / REPAIR KIT / REPARATURSATZ CLA-KIT X44A Standard (Cartouche, Screen, Sieb 0,2)
Page 39
® CLA-VAL RB-117 Accessoires - Accessories - Zubehör PN 10 - 16 - 25 - 40 Robinet de barrage à bille Corps laiton nickelé ou inox, mécanisme interne en inox Isolation Ball Valve Stainless steel or nickel plated body, stainless steel 303 trim Kugelhahn Gehäuse aus vernickeltem Messing oder Edelstahl, Innenteile aus Edelstahl...
Page 41
CLA-VAL Form Valve Specification CLA-VAL MAIN VALVE NGE-316 TYTAN 1 ¼" 1 ½" 2" 2 ½" 3" S 600 S 700 S 800 M 900 M 1000 L 900 L 1000 L 1200 VALVE INSTALLATION LEVEL CONTROL INSTALLATION Reservoir Reservoir...
Page 42
CLA-VAL Form Valve Specification STANDARD CLA-VAL VALVES: Catalog and Website Downstream Control Upstream Control Flow Rate Control Level Control 90-01 50-01 40-01 100-CF9 ABLM 90-CF9 ABELM 50-CF9 ABGLM 40-CF9 ABCLM 113-CF9 ABLM 91-01 51-01 41-01 427-01 ABLM 93E/D-01 AELN 58E/D-01...
Page 43
PT1: Test Pressure 1: Pressure test used for: ↑ Pilot system pressure test. PT2: Test Pressure 2: Pressure test used for: → Seat tightness test. ↓ Diaphragm tightness test. TYPE OF FLUID AND CLA-VAL STANDARDS Drinking water Industrial water Brackish water Temperature:...
Need help?
Do you have a question about the 90-01 and is the answer not in the manual?
Questions and answers
where is the noise data??? for CLA-VAL 90-01
I HAVE 90-01 2-1/2" VALVE AND NEEDS A REPLACEMENT VALVE BUT WANTS IT SET AT 125# WOULD THAT HAVE TO DO WITH SPRING RANGE SINCE WE USALLY SUPPLY 30-300 ON VALVES