3. Crimp the Fork terminals to the cable. (Fig. C)
4. Tighten the two Fork terminals beneath the two
Remote controller terminal screws on the back of
the main body. (Fig. D-1)
5. Cut out the inlet for the remote controller cable
from the bottom of the main body. (Fig. D-2)
6. Place the Main body back on the Back plate, with
the Remote controller cable running out of the
bottom inlet.
Fig. D-2
Inlet for the remote
controller cable
<How to connect the remote controller to the water heater>
1. Disconnect power supply from the water heater.
2. Take off the water heater's front cover.
3. Locate the two terminals for the remote controller in the water heater. (Refer to the Fig. E-1 and E-2.)
4. Put the remote controller cable through the hole at the bottom of the casing of water heater from
outside.
5. Secure both terminals on the controller cable to the terminals in the cabinet as shown below.
(Secure them underneath the screw terminals. No polarity.) See Figures E-1 and E-2.
* Do NOT jump or short-circuit the wires, or the computer will be damaged.
6. Replace the water heater's front cover securely.
Fig. E-1
110C and
310C models
Connect other end to these terminals
Cut out
100209924
(TM-RE42)
23
Fig. C
Remote controller cable
Fig. D-1
Remote controller
terminals
Remote controller cable
Fig. E-2
510C model
Connect other end to these terminals
Page
Installation Manual
Installation
1-3/8 Inch
(35 mm)
Fork
Terminals
1-5/8 Inch
(41 mm)
Two fork terminals
100209924