Mitsubishi Electric PLA-A12EA7 Service Manual page 104

P-series
Hide thumbs Also See for PLA-A12EA7:
Table of Contents

Advertisement

10
AIR FLOW DATA
PKA-A12HA7
Airflow distribution
<Cooling mode>
<Heating mode>
Due to continuing improvement, above specification may be subject to change without notice.
104
Air volume: high
Air direction: auto (upward air flow)
0.6(2.0)
0.6(2.0)
0.9(3.0)
0.9(3.0)
0.3(1.0)
0.3(1.0)
6000
5000
(236.22)
(196.85)
Air volume: high
Air direction: auto (downward air flow)
6000
5000
(236.22)
(196.85)
P-Series (March 2017)
1.5(4.9)
1.5(4.9)
4000
3000
2000
(157.48)
(118.11)
(78.74)
Floor distance [ mm (inch) ]
0.3(1.0)
0.3(1.0)
0.3(1.0)
0.3(1.0)
0.9(3.0)
0.9(3.0)
4000
3000
2000
(157.48)
(118.11)
(78.74)
Floor distance [ mm (inch) ]
[m/s(ft/s)]
[m/s(ft/s)]
2.1(6.9)
2.1(6.9)
1000
0
(39.37)
[m/s(ft/s)]
[m/s(ft/s)]
2.1(6.9)
2.1(6.9)
1.5(4.9)
1.5(4.9)
1000
0
(39.37)
© 2017 Mitsubishi Electric US, Inc.