Danger to life due to fire or explosion.
There is always a certain risk with electric devices that a fire may occur,
danger
even though the greatest attention has been paid to precluding this during
development.
Do not install the PowerRouter:
• on flammable construction materials,
• in areas where highly flammable materials are stored,
• in potentially explosive areas!
The PowerRouter weights 15.2 kg. Ensure that the mounting surface is
strong enough to hold the weight of the PowerRouter. Do not mount the
PowerRouter on plasterboard (sheetrock) or thin wood panelling.
Do not install the PowerRouter during periods of precipitation or high
humidity (>95%).
Moisture trapped within the location may cause corrosion and damage to
the electronic components.
If you are installing the PowerRouter in a cabinet, closet, or other relative-
ly small enclosed area, sufficient air circulation must be provided in order
to dissipate the heat generated by the unit.
To prevent electrical shock or other injury, check for existing electrical or
plumbing installations in the walls before drilling mounting holes for the
PowerRouter.
i
The PowerRouter is intended for operation in an environment having a
maximum ambient temperature of 40 °C.