Vermont Castings 1975CE CE Homeowner's Installation And Operating Manual
Vermont Castings 1975CE CE Homeowner's Installation And Operating Manual

Vermont Castings 1975CE CE Homeowner's Installation And Operating Manual

Defiant non-catalytic / catalytic woodburning stove

Advertisement

0968
Defiant cover
11/00
SaFeTy NoTice: iF ThiS appliaNce iS NoT pRopeRly iNSTalleD, opeRaTeD aND MaiN-
TaiNeD, a hoUSe FiRe May ReSUlT.
To ReDUce The RiSk oF FiRe, Follow The iNSTallaTioN iNSTRUcTioNS. FailURe To
Follow iNSTRUcTioNS May ReSUlT iN pRopeRTy DaMage, boDily iNjURy oR eveN
DeaTh. coNTacT local bUilDiNg oFFicialS aboUT ReSTRicTioNS aND iNSTallaTioN
iNSpecTioN ReqUiReMeNTS iN yoUR aRea.
Do Not Discard This Manual: Retain for Future Use
Defiant
Non-catalytic / catalytic
woodburning Stove
Model 1975ce
Homeowner's
Installation and

Operating Manual

For use in Europe
®
30005554 7/11 Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings 1975CE CE

  • Page 1: Operating Manual

    Defiant ® Non-catalytic / catalytic woodburning Stove Model 1975ce Homeowner’s Installation and Operating Manual For use in Europe 0968 Defiant cover 11/00 SaFeTy NoTice: iF ThiS appliaNce iS NoT pRopeRly iNSTalleD, opeRaTeD aND MaiN- TaiNeD, a hoUSe FiRe May ReSUlT. To ReDUce The RiSk oF FiRe, Follow The iNSTallaTioN iNSTRUcTioNS.
  • Page 2: Table Of Contents

    At MHSC, we share that joy and appreciation for the hearth. We assure you that your cast-iron Vermont Castings stove has been made with the utmost care and will provide you with many years of service.
  • Page 3: Specifications

    Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® Specifications Defiant Model 1975ce Nominal heat out put ....9.6 kW (33,000 BTU/hr) Width (leg-to-leg) ........8 mm (3”) Minimum flue draught ......1 Pa (0.048” WG) Depth (leg-to-leg)........483 mm (19”) Mean flue gas temp ........ 316° C (601° F) Height to top of flue collar ......760 mm (30”) Efficiency (Space heating) with Catalyst ....
  • Page 4: Installation

    Vermont Castings’ stove indicates the stove has performance often results. An Outside Air Adapter Kit for been tested to current standards. The test standard is the Defiant is available from your local Vermont Castings EN1340:001 + A:004 for Europe. Clearance and dealer.
  • Page 5 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® what kind of chimney to Use prefabricated chimneys You must connect the Defiant to a code-approved masonry These should be an internal diameter of 03 mm (8”) and chimney with a flue liner, to a relined masonry chimney that be of the twin wall insulated construction that has been meets local codes, or to a prefabricated metal chimney.
  • Page 6 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® Single-wall chimney connectors Flue Pipes with a spigot and socket joint should be fitted with the socket facing upwards, to contain condensates • Begin assembly at the flue collar of the stove. Insert the and moisture within the flue.
  • Page 7 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® Chimney Flue Thimble Sleeve Flue Chimney Connector Elbow Flue Liner Keep Slip Pipe sleeve end flush Thimble with flue Standard tile Connector Oval to Round Adapter ST43 Flue Collar Fig. 6 The thimble, made of either ceramic or metal, must be cemented securely in place.
  • Page 8 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® Chimney Connector Shields Flexible Connector Mantel Shield Fireplace Adapter Kit “Positive Con- nection” Mantel * Check These Clearances Seal this off ST45 ST44 Fig. 8 In this installation, the chimney connector enters the firepalce opening and then connects to the chimney.
  • Page 9 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® hearths This appliance must be installed on to hearth that meets the requirements of Part J of the Building Regulations 000 (Combustion Appliances and Fuel Storage Systems). This can be achieved by ensuring that the hearth is constructed and sized in accordance with the guidelines included in sec- tion  of approved document ‘J’.
  • Page 10 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® In addition, furnishings and other combustible materials Minimum rear clearance from combustible walls (e.g. must be kept away from the stove as well. In general, a timber framed or studded walls) 254 mm (10”) mea- distance of 119 mm (48”) must be maintained between sured from the rear edge of the stove top.
  • Page 11 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® at least at least at least 3 x D 3 x D 1.5 x D at least 1.5 x D Fluepipe at least 1.5 x D at least 1.5 x D Air space of at least 1 mm between noncombustible shield plan without at least 1.5...
  • Page 12: Assembly

    Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® assembly Set Up your Stove Cast iron stoves are heavy, and it will take two to four people to move your Defiant into position. Wipe the protective coating of oil from the griddle with a clean dry rag or a paper towel.
  • Page 13 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® Fan kit installation Air Deflector Air Deflector 1. Attach the fan assembly at the bottom edge of the in- Sheet ner back with two () 1/4-0 x 3/4” hex head screws. Metal .
  • Page 14 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® installing or Removing catalyst 1. Remove the access cover by gently lifting up and pull- ing out from the bottom edge. (Fig. 1) . Remove the inner cover by pulling it straight out. (Fig. 3.
  • Page 15: Operation

    Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® operation The Defiant controls Two controls regulate the performance of the Defiant: a primary air control supplies oxygen for the fire, and a low heat damper directs air flow within the stove to activate and deactivate the catalytic combustor.
  • Page 16 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® combustion system in your Defiant work together to pro- use a full load of dry slab wood or scrap wood. For long duce optimum conditions for secondary combustion. burns, use a mix of dry and moderately dry wood. When the damper is closed, smoke travels through the cat- Two ways to add Fuel alytic element, which causes ignition of smoke at tempera-...
  • Page 17 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® • caUTioN: The Defiant will be hot while in operation. Remove the ash pan, making sure to keep it level. keep children, clothing and furniture away. contact • To keep the cover from sliding off and to keep ash from may cause skin burns.
  • Page 18: Maintenance

    If you need to replace the glass, use only the high tempera- dure. ture 5 mm ceramic glass supplied by Vermont Castings. Do not use substitutes. care of the cast iron Surface Removing the glass An occasional dusting with a dry rag will keep the painted cast iron of your Defiant looking new.
  • Page 19 If you need to change a gasket, first obtain an appropri- . Loosen the set screw with a 1/8” Allen wrench. 11/00 ate replacement from your Vermont Castings’ Authorized 3. Rotate the pawl 180°. Replace the lock nut. Tighten the Dealer.
  • Page 20: The Chimney System

    Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® all gasketed construction gaskets Other gaskets form seals between all other non-moving parts, but these are not subject to the same wear and deterioration as gaskets on moving parts. It is unlikely that you will ever need to replace these gaskets unless the involved parts are disassembled and then put back together.
  • Page 21 If you cannot inspect or clean the chimney yourself, con- aNNUal SpRiNg cleaNiNg: tact your local Vermont Castings dealer or a professional • Disassemble the chimney connector and take it outdoors chimney sweep.
  • Page 22: The Catalytic Element

    You may have to run your stove hotter (more air) to achieve replaced. Call your local Vermont Castings Authorized acceptable performance using green or wet wood. Dealer for a replacement element.
  • Page 23 Contact your nearest Vermont Castings’ Authorized Dealer for informa- tion about a replacement element. NoTe: Use only the replacement catalyst supplied by a Vermont Castings dealer.
  • Page 24 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® 5220 Defiant 2N1 parts MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Defiant Noncatalytic/catalytic woodburning Stove 30005554...
  • Page 25 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® Defiant Noncatalytic/catalytic woodburning Stove Model 1975ce (continued) item Description part Number item Description part Number 49. Pawl Assy 3/4 short adj 30005157 1. Brick Support Bracket 3000579 49a. Spring Washer 63D0069 . Griddle Gasket 103668 50.
  • Page 26 Defiant 1975CE Non-Catalytic / Catalytic Woodburning Stove ® Defiant Noncatalytic/catalytic woodburning Stove Model 1975ce (continued) Shell enamel parts - Defiant Model 1975 brown part Name classic biscuit bordeaux ebony Majolica 3000834 3000874 3000915 3000894 30004837 Left Side 300083 300087 3000913 300089 30004834 Right Side...
  • Page 27: Warranty

    50 % If a defect is noted within the warranty period, the customer should 37 - 48 months contact a Vermont Castings Authorized Dealer or MHSC if the purchase 49 - 60 months was direct with the following information: 61 - 7 months 1.
  • Page 28 MhSc 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...

This manual is also suitable for:

Defiant 1975cDefiant 1975ce

Table of Contents