4. Troubleshooting

4-2 Electrical Malfunction

Safety error
No power
or
No display
*Check terminal block voltage.
AC 240V/120V or AC208V/120V
*Thermostat open check. (150°c / 0°c )
*Check the pin voltage of connector
(CN01) on Main PCB.
(Input voltage : 120V)
Check the Low voltage Transformer
Low Voltage Transformer
Low Voltage Transformer
IC03(7805)
IC03(7805)
IC02(7812)
IC02(7812)
(Terminal Block)
(Terminal Block)
L1
L1
(Black)
(Black)
No
Yes
No
Yes
Yes
No
**Reconnect and replace or
repair harness is damaged
Check whether varistor(ZNR1) on
main PCB has been damaged.
ZNR1
ZNR1
(Varistor)
(Varistor)
Connector
Connector
CN01(AC 120V)
CN01(AC 120V)
42
L1
L2 : 240V
L2
L2
L1
N : 120V
(Red)
(Red)
L2
N : 120V
N
N
(White)
(White)
* Reset the circuit breaker
or check main power.
END
* replace Thermostat.
Thermostat
Thermostat
(150/0)
(150/0)
Yes
* replace Main PCB.
END