Specifications - Sony BKM-61D Operation Manual

Table of Contents

Advertisement

Specifications

General
Voltage
+5 V, ±6 V (supplied from the monitor)
Power consumption
6 W max.
Operating conditions
Temperature
0°C to 35°C (32°F to 95°F)
Optimum temperature
20°C to 30°C (68°F to 86°F)
Humidity
0% to 90% (no condensation)
Pressure
700 hPa to 1060 hPa
Storage and transport conditions
Temperature
–10°C to 40°C (14°F to 104°F)
Humidity
0% to 90%
Pressure
700 hPa to 1060 hPa
Maximum external dimensions (w/h/d)
25 × 256 × 248 mm
1
(1 × 10
Mass
approx. 930 g (2 lb 1 oz)
Input/output connectors
Digital input
BNC × 2, with monitor output × 1
Analog input
BNC × 3, high impedance, with loop-
through output
Signal characteristics
Analog composite and Y/C signals
Signal level
Analog composite
1 Vp-p +2 dB/–6 dB
Y/C
Y: 1 Vp-p +2 dB/–6 dB
C (NTSC): 0.286 Vp-p +2 dB/–6 dB
(burst signal level)
C (PAL): 0.3 Vp-p +2 dB/–6 dB (burst
signal level)
Luminance signal
Frequency characteristics
Analog composite
Filter off: 50 Hz to 5 MHz ±2 dB
Filter on: –30 dB relative to sub carrier
frequency
Y/C
Y: 50 Hz to 5.75 MHz ±2 dB
Chrominance signal
Demodulation axis
R-Y/B-Y
Chrominance signal band
R-Y: 1.3 MHz –3 dB
B-Y: 1.3 MHz –3 dB
Chroma phase adjustment range
NTSC: ±15° min.
DG (differential gain)
APL 10% to 90%
2% max. (Y: amplitude 1 Vp-p)
7
/
× 9
/
inches)
8
8
DP (differential phase)
APL 10% to 90%
2° max. (Y: amplitude 1 Vp-p)
Chrominance signal/luminance signal
Delay time error
35 nsec max.
Gain error
5% max.
Aperture compensation
6 dB min. (5 MHz)
Return loss
–40 dB max. (7 MHz)
Digital component (525, 625) and digital
composite (NTSC, PAL) signals
Component
Sampling frequency
Y: 13.5 MHz
R-Y/B-Y: 6.75 MHz
Frequency characteristics
Y: 50 Hz to 5.75 MHz ±1 dB
R-Y/B-Y: 50 Hz to 2.75 MHz ±1 dB
Chrominance signal/luminance signal
Delay time error: 30 nsec max.
Gain error: 5% max.
Aperture compensation
6 dB min. (5 MHz)
Composite
Sampling frequency
NTSC: 14.3 MHz
PAL: 17.7 MHz
Frequency characteristics
Y: 50 Hz to 5 MHz ±2 dB
R-Y/B-Y: 1.3 MHz –3 dB
Chrominance signal/luminance signal
Delay time error: 35 nsec max.
Gain error: 5% max.
Aperture compensation
6 dB min. (5 MHz)
Quantization
10 bits/sample
Transmission distance
200 m (approx. 656 ft) max. (When
using 5C-2V coaxial cables (Fujikura,
Inc.) or equivalent.)
Return loss
–15 dB max. (5 to 270 MHz)
Accessories supplied
Operation Manual (1)
Design and specifications are subject to change without
notice.
BKM-61D SDI/Analog Multi Input Adaptor
17

Hide quick links: