en | 8 | Installation and Operating Instructions | Power Max 2 Charging Station

5 Specifications

Model
Charging Interface
Input Rating
Wiring for Hard-wired Models
Wall Plug for Cord-connected Models
Output Rating
Standby Power
Metering
Internal Residual Current Detection
Upstream Breaker
Electrical Protection
Status Indicators
Buttons/Switches
Option: Network Interface
Operating Temperature
Humidity
Charging Cable Length
Ingress Protection
Cooling
Dimension (W×H×D)
Net Weight
Certificate
579367 | REV A | 25.07.2016
EL-51866-30XX
SAE J1772 compliant plug
208-240 Vac, single-phase,
30 A max, 60 Hz
L1, L2, and Ground, hard-wired with terminal block; bottom-fed
NEMA 6-50P
208-240 Vac, single phase, 30 A max.,
60 Hz, 7.2 kW
<5W
Embedded non-revenue grade meter with 1% accuracy
20 mA CCID per UL 2231
2-pole 40 A breaker on dedicated
circuit, non-GFCI type (if hard-wired)
Over current, short circuit, over voltage, under voltage, ground fault,
surge protection, over temperature
AC present, charging, fault
Charger on/off, stop charging
WLAN
-22°F to +122°F (-30°C to +50°C)
95% related humidity, non-condensing
18 ft (5.5 m) or 25 ft (7.6 m) straight cable
Type 3R
Natural cooling
12.6×10.3×4.5 in. (320×260×115 mm), excluding charging cable, mount-
ing plate, and cable holder
5 lb (2 kg) excluding charging connector and cable
UL, cUL
EL51866-40XX
208-240 Vac, single-phase,
40 A max, 60 Hz
208-240 Vac, single phase, 40 A
max., 60 Hz, 9.6 kW
2-pole 50 A breaker on dedi-
cated circuit, non-GFCI type

Advertisement

Table of Contents
loading

Table of Contents