Introduction; Applications; Important Safety Warnings And Instructions; About The Charger - Bosch Power Max 2 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

1

Introduction

The Power Max 2 Charging Station is designed for the
North American market to charge plug-in electric vehicles
(PHEV) and battery electric vehicles (BEV).
This document provides instructions for the Power Max 2
Charging Station and is not for use for any other product.
Before installation or use of this product, you should review
this manual carefully and consult with a licensed contractor,
licensed electrician, or trained installation expert to ensure
compliance with building codes and safety standards.

1.1 Applications

} Residential
} Private and public parking facilities
} Fleet
} Shopping malls and retailers
} Workplace
Please read and follow these safety warnings and operating
instructions carefully before operating the Power Max 2
Charging Station. Failure to follow these instructions may
result in serious injury or property damage.
2
Important Safety Warnings
and Instructions
IMPORTANT SAFETY INSTRUCTIONS. SAVE
THESE INSTRUCTIONS.
WARNING!
Disconnect electrical power before installing
the Power Max 2 Charging Station . Failure to do
so may cause physical injury or damage to the
electrical system and charging unit .
} Read all the instructions before using this product.
} Children should be supervised when this product is
used around children.
} Do not put fingers into the EV connector.
} Do not use this product if the flexible power cord or EV
cable are frayed, have broken insulation, or display any
other signs of damage.
} Do not use this product if the enclosure or the EV connector
is broken, cracked, open, or show any other signs of damage.
} A device employing pressure terminal connectors for
field wiring connections shall be provided with
instructions specifying a range of values or a nominal
value of tightening torque to be applied to the clamping
screws of the terminal connectors.
CAUTION
To reduce the risk of fire in hard-wired units,
connect the unit only to a circuit provided with
maximum branch circuit overcurrent protection
as show below in accordance with the National
Electrical Code, ANSI/NFPA 70 .
Installation and Operating Instructions | Power Max 2 Charging Station | 5 | en
Model
EL -51866-40XX
EL -51866-30XX
CAUTION
To reduce the risk of fire in cord-connected units,
connect only to a circuit provided with maximum
branch circuit overcurrent protection as shown
below in accordance with the National Electrical
Code, ANSI/NFPA 70 .
Model
EL -51866-40XX
EL -51866-30XX
} The Power Max 2 Charging Station shall be installed only
by a licensed contractor, and/or a licensed electrician in
accordance with all applicable state, local and national
electrical codes and standards.
} Before installing the Power Max 2 Charging Station,
review this manual carefully and consult with a licensed
contractor, licensed electrician and trained installation
expert to ensure compliance with local building
practices, climate conditions, safety standards, and
state and local codes.
} Use appropriate protection when connecting to the main
power distribution cable.
3

About the Charger

1
2
1 .
On/Off switch
2 .
Status indicator
Ready
}
Charge
}
}
Fault
3 .
Charging plug
SAE J1772 compliant
}
Current Rating
50 A
40 A
Current Rating
50 A
50 A
3
579367 | REV A | 25.07.2016

Advertisement

Table of Contents
loading