Additional Information; Network Setting (El-51866-4025P Only); Log File Download And Firmware Upgrade By Usb; Auto Restart - Bosch Power Max 2 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

en | 10 | Installation and Operating Instructions | Power Max 2 Charging Station
7

Additional Information

7.1 Network Setting (EL-51866-4025P only)

For models equipped with WLAN functionality, it is critical
to configure WLAN parameters in accordance to local
settings. Consult network administrator to get WLAN SSID
and password. Use the supplied software tool to compose
the WLAN configuration file and save to a USB flash drive.
Insert the USB flash drive to the USB port during charger
installation. Refer to the instructions of the supplied soft-
ware tool for more details.
7.2 Log File Download and Firmware
Upgrade by USB
When a USB flash drive is inserted to the USB port of the
charger, system log file is downloaded automatically to the
flash drive. Submit system log file to technical support
when requested.
Latest update of system firmware is made available on a
designated website. Download and store the firmware
package on the USB flash drive and follow the instructions
to conduct firmware upgrade.

7.3 Auto Restart

When a charging session is interrupted due to a temporary
error condition, the Power Max 2 Charging Station will
automatically retry and restart charging when the cause of
the temporary error condition returns to normal. Status
indicator remains flashing in red until the error condition is
resolved.
Temporary error conditions include: Over Current, Over
Voltage, Under Voltage, Over Temperature.
For Over Current condition, there are two automatic retries
allowed for each charging session.
When a charging session is interrupted due to a CCID trip,
the Power Max 2 Charging Station will retry after 15 min-
utes, for up to 4 times.

7.4 Power Outage Recovery

When power resumes after an outage, the Power Max 2
Charging Station restarts automatically with delay ranging
from 5 to 100 seconds. The delay is designed to avoid
impacting the utility grid when multiple chargers in the
same area attempt to resume charging simultaneously.
There is no need to authenticate the user again.

7.5 Remote Control (EL-51866-4025P only)

For models equipped with WLAN functionality, charg-
ing capability of a Power Max 2 Charging Station can
be configured remotely by the back-end management
system.
579367 | REV A | 25.07.2016
8

Troubleshooting

Situation
1.
Make sure the AC power input is
connected correctly and the AC power
Power
is within operating range of the unit
indicator
2.
Power cycle the Power Max 2 Charg-
does not
ing Station
illuminate
3.
If the problem persists, contact
Customer Support
1.
Make sure the charging plug is
inserted firmly in the EV charging inlet
2.
If the Power Max 2 Charging Station is
connected to a back-end management
system, check network connectivity
Charging
and make sure the Power Max 2
indicator
Charging Station is not under a remote
does not
control scheme
illuminate
3.
If the Charging indicator does not
illuminate after 10 seconds, power
cycle the Power Max 2 Charging
Station and plug in the charging plug
4.
If the situation persists, contact
Customer Support
1.
There is a temporary error
2.
Wait until the temporary error is
resolved and the Power Max 2
Charging Station returns to normal
condition. It usually takes less than
Fault
10 seconds.
indicator
3.
If the Power Max 2 Charging Station is
flashes
connected to a back-end management
red while
system, check network connectivity
charging
4.
If the status indicator doesn't return to
green, power cycle the Power Max 2
Charging Station
5.
If the situation persists, contact
Customer Support
1.
There is a critical error (CCID trip or
Relay failure)
Fault
2.
Unplug the charging connector
indicator
3.
Power cycle the Power Max 2 Charg-
is solid
ing Station
red
4.
If the situation persists, contact
Customer support
Action

Advertisement

Table of Contents
loading

Table of Contents