Download Print this page

Carrier 50PM20 Installation Instructions Manual page 43

Single package rooftop units electric cooling with electric heat option and electromechanical controls with puron (r-410a) refrigerant

Advertisement

,..,Q
I
0
0
0FC2
I_qo
EOUIP
_
GROUND
i
OR
OISCONNECT
_ACRBREAKER
i
i
7
COMPONENT
CLO A_
D
ARRANGEMENT
'O'E' CO""_<_<E
O_,_E_J
CONTROL BOX
ONIOFF SWITCH
COMPRESSOR CONTACTORS
ENTUALPY
SAT.
OEMS
(24,28
ONLYI
CONDENSER C OILS
THERMISTOR LOCATIONS
(READ REND)
F
ANOAk,
'RNT_Y
_ONTROL
\
FREEZESTAT
LOCATIONS
FVAPORATOR RETU_ BEND ENO
X_SPEED
CONFROL
THERMISTOR LOCATION
PLUG LOCATION REFERENCE
eLI
PL3 HEAT SECTION PARTITION
(HEAT CONTROLS)
FAN SECTION
PL4
INDOOR EAN MOTOR}
CONDENSERSECTION
PL5 (OEM1,
B,
B)
PL6 CONDENSER_CTiON
{OFM4,
5,
PLY ECONOMIZER SECTION
(ECONOMIZER MO[ORI
POWEREXHAUST SECTION
PL9 (POWER EXNAUS] MOTORS)
PLIO CONDENSERSECTION
__
(OFM1)
PLII CONDENSERSECTION
(OFMR)
PL12 CONDENSER SECTION
(OFM3)
P[IR CONDENSER SECTION
(OFM4)
PL14 CONDENSER SECTION
(OFW5)
PL15 CONDENSERSEEIlON
(OFM6)
FAN SECTION
PLI6 (FAN STATUS ACCESSORY)
PLIY ECONOWIZER SECTION
(R-POSITION HAMPER)
OEM2 (24_80NLYI
/
Do
oQ
o
o)
SMOKE CONTROL :
EET
_
CONVE_d'ENCE
TERM MAL BLOCK
o
TERMINAL
(UNMARKED)
ERM MAL _MARKED
°
SPLICE
FACIORY
WIRING
FIELD
WIRING
lO INDICATE
COMMON POTENT AL
ONL V,
NOT TO REPRESENT
WIRING
• --
0
NDICATE
FlOP
OR ACCESSORY
i
/
FA_NST'A_
SMOKE CON[R"_'mL:
,,
C_NI'ENCE
NPSB
LPS A
_ER
SY_T'_'_'_
TRAN_FO_
CCHBI
GAS HEATN_
EVAP CIRCUIT
CONFIGURATION
AU AX
CIRCUIT A
FU
FUSE
AUX]LLARY CONTACT
GNB
GROUND
NOTES:
AL
AMBIENT LIMIJ
GV
GAS VALVE
I,
FACTORY WIRING [S IN ACCORDANCE WITH THE NATIONAL
_B
CIRCUIT B
HPS
NIGH PRESSURE SWITCH
ELECTRICAL CODES ANY FIELD MODIFICATIONS
OR
C
CIRCUIT C
I
IGNITOR
ADDiT!ONS MUST BE IN COMPLIANCE WITH ALL APPLICABLE
_r
COMPRESSOR,CONTACTOR
IAO
INDOOR AIR QUALITY
CODES
CAP
CAPACITOR
IOM
INDUCED BRAF[ MOTOR
2
USE 7S°C MiN WIRE FOR FIELD POWERSUPPLY, USE COPPER
CD
CIRCUIT BREAKER
IDR
INDUCED DRAFT RELAY
WIRES FOR ALL UNITS
CCH
CRANNCASE HEATER
IEC
INDOOR FAN CONTACTOR
B
ALL CIRCUIT
BREAKERS "MUST TRi ° AMPS" ARE EQUAL TO
CLO
COMPRESSOR LOCKOUT
IECB
INDOOR FAN CIRCUIT
BREAKER
OR LESS THAN IS6% RLA
COMP
COMPRESSOR
INN
INDOOR FAN MOTOR
4
COMPRESSOR AND FAN MOTORS ARE THERMALLY PROTECTED--
CR
CONTROL RELAY
]RN
INDOOR RELATIVE HUMIDITY
THREE PHASE NO[ORS PROTECTEDAGAINST PRIMARY SINGLE
DU
DUMMY [ERMiNAL
ICE
INIEGRATEB GAS CONTROLLER
PHASE CONDITIONS
ECB
ECONOMIZER CONTROL BOARD
LPS
LOW PRESSURE SWITCH
5
THE CLO LOCKS OUT THE COMPRESSOR TO PREVENT SHORT
ECS
FAN CYCLING SWITCH
LS
LIMIJ
SWlTCN
CYCL]NG ON COMPRESSOR OVERLOAD AND SAFETY DEVICES;
RPT
FREEZE PROTECTION THERMOSTAT ORE
OUTDOORFAN CONTACTOR
BEFORE REPLACING ELO, CHECK THESE DEVICES
ES
iLAME SENSOR
• SUPPLY' _MONE
_AN ,SIATUS_ OUT ET TRANSFORMER
CCHAI
LPS A [VAP CIRCUIT CONFIGURATION
_
''
_)U[_ •
,J
ELECTRIC/NO HEAT ONLY
_F(T_I_ _ "_'?'s_T_
OFM
OUTDOORFAN MOTOR
TMERMOSTAT/IQC MARKINGS
ORN
OUTDOORRELATIVE HUMiDiTY
BM
BLOWER MOTOR
Wl
_sf
STAGE OE HEATING
PEE
POWEREXHAUST CONIAE[OR
C
COMMON
W2
Bnd STAGE OF HEATING
PEN
POWEREXHAUST MOTOR
CM
INDUCER MOEOR
X
ALARM OUTPUT
PL
PLUG
CS
CENTRIFUGAL SWITCH
Y1
]s_
STAGE OF COOLING
PLP
PHASE LOSS PROTECTION
G
FAN
Y2
2ridSTAGE OF CO0{]NG
RAT
RUURN
AIR SENSOR
iFO
INDOOR FAN ON
RS
ROLLOUT SWITCH
L1
LINE 1
SAT
SUPPLY AIR TEMPERATURE
R
THERWOSTATPOWER
SS
SPEED SENSOR ([DM)
R]
POWER SUPPLY
TB
TERM[NA_ BLOCR
SS
SPEED SENSOR
TBR
TIME DELAY RELAY
W
THERMOSTAT HEAT
TRAN
TRANSEORMER
50TG505337 Rev. 2,0

Advertisement

loading

This manual is also suitable for:

50pm2450pm28