Charging Chart; Disposal - Truma SDC 10 Operating Instructions & Installation Instructions

Solar dual battery charger
Table of Contents

Advertisement

Available languages

Available languages

Charging voltage
Battery type, settable
Absorbtion phase *
Float phase *
Equalisation charging phase *
Bulk phase reconnection
voltage *
Maximum charging voltage * 16,6 V
Temperature compensation *
Temperature sensor
(measuring range)
Mechanical values
Protection type
Installation
Weight
Connection terminals
Dimensions L x W x H
Humidity
(not condensing)
Gel
AGM
Liquid
sealed
14,2 V
14,4 V
14,6 V
13,8 V
13,8 V
13,8 V
14,6 V
14,8 V
13,3 V
-30 mV / K
-40 °C – +125 °C
SDC 10
SDC 20
IP 30
Wall mounted
200 g
230 g
4 mm²
154 x 76 x 37,5 mm
95 %

Charging chart

HL = Bulk phase
NL = Absorbtion phase (2 hours)
EL = Float phase
U[V]
U
NL
U
EL
U
HL
HL
0
Fig. 2: Charging chart (basic curve)
The right to effect technical modifications is reserved!

Disposal

The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.
NL
EL
t[h]
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdc 20

Table of Contents