Improper Use; Battery Care; Device Elements - Truma SDC 10 Operating Instructions & Installation Instructions

Solar dual battery charger
Table of Contents

Advertisement

Available languages

Available languages

Improper use

The device is not suitable for charging
– 6 V batteries or 6 V lead accumulators
– non-chargeable batteries
– nickel-cadmium batteries.
If batteries with a rated voltage of 6 V are charged with the
device, gassing occurs immediately. An explosive gas can be
created.
The device is only suitable for regulating solar modules. Do
not connect any other voltage sources (e.g. main voltage
230 V) to the device. This may destroy the device and/or
sources. If any other voltage sources are used together with
the device, please ask your dealer.

Battery care

(also maintenance-free batteries)
The following points should be observed to extend the
battery life:
– Batteries should be fully charged before and after being
used.
– In the case of longer standstills (without sunshine), discon-
nect the battery and charge for 24 hours at the latest every
12 weeks.
Store fully charged batteries in a cool but frost-free place
during the winter and recharge regularly (every 12 weeks).
18

Device elements

B2
H1 H2
Solar Dual Battery Charger
+
remote temp. sensor
1
X1
X2
Fig. 1: Device elements
H1 LED- Function display battery 1 (supply battery)
H2 LED- Function display battery 2 (starter battery)
H3 LED – Battery type - AGM, gel, liquid (liquid electrolyte)
H4 LED – Charging current distribution
H5 LED – PWM charging frequency
H6 shows the values of H3, H4, H5 as numbers
T
Query / change operating mode
B2 Internal temperature sensor
X1 Connection for temperature sensor B1
X 2 Connection for battery 1 (supply battery)
X3 Connection solar module
X4 Connection battery 2 (starter battery)
X5 No function
H3
H4
H6
H5
T
SET
+
– +
2
remote meter connection
X3
X4
X5