Configuration procedure

To enable TRILL:
Step
1.
Enter system view.
2.
Enable TRILL globally
and enter TRILL view.
3.
Return to system view.
4.
Enter Layer 2 Ethernet
or aggregate interface
view.
5.
Enable TRILL on the
port.

Configuring the system ID and nickname for an RB

The system ID and nickname of an RB are identifiers of the RB in the TRILL network.
System ID—Unique identifier of an RB in the TRILL network. The system ID can be automatically
assigned or manually configured.
Nickname—Address of an RB in the TRILL network. The address can be automatically assigned or
manually configured. When multiple RBs in the TRILL network have the same nickname, the RB with
the highest priority uses the nickname. When the RBs also have the same priority, the RB with the
RB 1
Traditional Ethernet
switch
RB 3
Command
system-view
trill
quit
interface interface-type
interface-number
trill enable
Remarks
N/A
By default, TRILL is disabled globally.