Specifications
Control card, USB serial communication:
USB standard
USB plug
Connection to PC is carried out via a standard host/device USB cable.
The USB connection is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
The USB ground connection is not galvanically isolated from protection earth. Use only an isolated laptop as PC connection to
the USB connector on the drive.
Relay outputs:
Programmable relay outputs
Relay 01 Terminal number
Max. terminal load (AC-1)
Max. terminal load (AC-15)
Max. terminal load (DC-1)
Max. terminal load (DC-13)
Relay 02 Terminal number
Max. terminal load (AC-1)
Max. terminal load (AC-15)
Max. terminal load (DC-1)
Max. terminal load (DC-13)
Max. terminal load (AC-1)
Max. terminal load (AC-15)
Max. terminal load (DC-1)
Max. terminal load (DC-13)
Min. terminal load on 1-3 (NC), 1-2 (NO), 4-6 (NC), 4-5 (NO)
Environment according to EN 60664-1
1)
IEC 60947 part 4 and 5
The relay contacts are galvanically isolated from the rest of the circuit by reinforced isolation (PELV).
2)
Overvoltage Category II
0
10
3)
UL applications 300V AC2A
Cable lengths and cross sections for control cables
Max. motor cable length, screened
Max. motor cable length, unscreened
Maximum cross section to control terminals, flexible/ rigid wire without cable end sleeves
Maximum cross section to control terminals, flexible wire with cable end sleeves
Maximum cross section to control terminals, flexible wire with cable end sleeves with collar
Minimum cross section to control terminals
1)
For power cables, see electrical data tables.
Control card performance:
Scan interval
Control characteristics:
Resolution of output frequency at 0 - 1000Hz
Repeat accuracy of Precise start/stop (terminals 18, 19)
System response time (terminals 18, 19, 27, 29, 32, 33)
Speed control range (open loop)
Speed control range (closed loop)
Speed accuracy (open loop)
Speed accuracy (closed loop), depending on resolution of feedback device
Torque control accuracy (speed feedback)
All control characteristics are based on a 4-pole asynchronous motor
74
AF-650 GP Operating Instructions
1)
on 1-3 (NC), 1-2 (NO) (Resistive load)
1)
(Inductive load @ cosφ 0.4)
1)
on 1-2 (NO), 1-3 (NC) (Resistive load)
1)
(Inductive load)
1)
on 4-5 (NO) (Resistive load)
1)
on 4-5 (NO) (Inductive load @ cosφ 0.4)
1)
on 4-5 (NO) (Resistive load)
1)
on 4-5 (NO) (Inductive load)
1)
on 4-6 (NC) (Resistive load)
1)
on 4-6 (NC) (Inductive load @ cosφ 0.4)
1)
on 4-6 (NC) (Resistive load)
1)
on 4-6 (NC) (Inductive load)
1)
:
2)3)
Overvoltage cat. II
overvoltage category III/pollution degree 2
1.1 (Full speed)
USB type B "device" plug
2 Form C
1-3 (break), 1-2 (make)
240V AC, 2A
240V AC, 0.2A
60V DC, 1A
24V DC, 0.1A
4-6 (break), 4-5 (make)
400V AC, 2A
240V AC, 0.2A
80V DC, 2A
24V DC, 0.1A
240V AC, 2A
240V AC, 0.2A
50V DC, 2A
24V DC, 0.1A
24V DC 10mA, 24V AC 20mA
150m
300m
2
1.5mm
/16 AWG
2
1mm
/18 AWG
2
0.5mm
/20 AWG
2
0.25mm
/ 24AWG
AF-650 GP: 1 ms
± 0.003Hz
≤± 0.1ms
≤ 2ms
1:100 of synchronous speed
1:1000 of synchronous speed
30 - 4000rpm: error ±8rpm
0 - 6000rpm: error ±0.15rpm
max error±5% of rated torque