5.4 Mounting and Installation Procedure
To order replacement gaskets,
refer to the part number listed
in
Appendix
B.
Panel Thickness:
1.0 to 5.0 mm
(0.04 to 0.20 in)
IC755CxSO6RDx or IC755CxW07CDx
Panel Cutout Dimensions
Panel Thickness:
1.6 to 5.0 mm
(0.06 to 0.20 in)
IC755CxS12CDx Panel Cutout Dimensions
66
GFK-2847R
For public disclosure
Observe the following guidelines to properly mount and install the QuickPanel
Interface:
•
The enclosure should be of metal material.
•
The metal enclosure panel should ensure proper thickness and rigidity suitable to
minimize impact to the QuickPanel
•
The recommended torque for the plastic back cover and interior metal cover for the
10, 12, and 15" QuickPanel
serial port DIP Switches is 0.5 Nm (4.4 in-lb).
•
To avoid gasket degradation, limit repeated insertions or removals of the unit and
retightening of the mounting clips. For full protection, always use a fresh gasket.
•
The unit will not fit through the cutout with any cables connected, or with the power
supply plug inserted in the socket.
Caution
➢ ➢ To install the QuickPanel
Cut an opening in the panel according to the specifications in the following figures.
1.
Note Panel cutout tolerances are +0.50, –0.00 mm (+0.02, –0.00 in).
183.50 mm (7.22 in)
302 mm (11.89 in)
+
unit.
+
display units that is accessed for panel updates and
When installing the QuickPanel
careful attention while handling the unit so it does
not drop and damage the unit.
+
Panel Thickness:
1.6 to 5.0 mm
(0.06 to 0.20 in)
IC755CxS10CDx Panel Cutout Dimensions
Panel Thickness:
1.6 to 5.0 mm
(0.06 to 0.20 in)
IC755CxS15CDx Panel Cutout Dimensions
QuickPanel⁺ Operator Interface User Manual
+
Operator
+
into the panel, pay
266 mm (10.47 in)
379 mm (14.92 in)