Rotem Platinum plus User Manual
Hide thumbs Also See for Platinum plus:
Table of Contents

Advertisement

User's
Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Platinum plus and is the answer not in the manual?

Questions and answers

Deividas Jankys
March 5, 2025

Hello, can you please help, we have platinum plus version. Somebody set the password to the system and nobody knows the password. Is any chance to reset the password and create a new one or maybe it’s possible to reset all system. I was trying to find in manual, but I couldn’t so i wondering maybe You can help me. Thank you very much

1 comments:
Mr. Anderson
May 14, 2025

To reset the password for the Rotem Platinum Plus system, the owner must set a new password. However, once a password is entered or changed, it cannot be seen again by the owner or users. Only the owner has the ability to set new passwords.

This answer is automatically generated

Mr. Pan Aung Phyu
February 28, 2025

What I need to check if the main screen not show and only appear black or white color?

User image 67c131adcdc55
1 comments:
Mr. Anderson
May 14, 2025

If the main screen of the Rotem Plus shows only black or white (still screen), the analog input card should be replaced.

This answer is automatically generated

Summary of Contents for Rotem Platinum plus

  • Page 1 User’s Manual...
  • Page 2: Warning

    These are to operate critical systems even in case of a Rotem system failure. Neglecting to provide such back up will be regarded as the user’s willingness to accept the risk of loss, injury and financial damage.
  • Page 3: Table Of Contents

    Platinum Plus Table of Contents Warning......................2 Table of Contents...................3 Features ......................4 Introduction ....................5 Hot Key Functions ......................7 General Description ..................12 Standard Ventilation Mode ....................12 Precision Ventilation Mode....................13 Standard & Precision, Example ..................14 Other Devices........................15 Standard Mode Programming Guide............17 Where do I start? .......................
  • Page 4: Features

    Poultry House Control Features ROTEM Platinum Plus features: User Friendly Large 20 line X 40 Character Lighted Graphic Display 20 Key Keypad Standard and Precision Programs Extensive Historical and Management Information Collection Communications Programming Plug (Data Shuttle) Exceptional Lightning Protection...
  • Page 5: Introduction

    Platinum Plus Introduction The Platinum Plus is a full-featured Poultry House Control. The following sections introduce the primary features and operator screens. Main Screen The main screen has five parts. 1. The upper left part, Sensors, shows the individual sensor readings.
  • Page 6 The Numeric keys enter numbers and make choices in numbered menus. Several numeric keys perform special Hot Key functions. Enter The Enter key completes your entry or menu selection. The Platinum Plus recognizes numeric values when setting temperatures, times, etc. only after you push the enter key.
  • Page 7: Hot Key Functions

    Hot Key ‘1’ – Main Display Pressing the ‘1’ key at one of the other hot key displays returns the Platinum Plus to the standard display. Hot Key ‘2’ – Curve Status Press the ‘2’ key at the main display to show the ‘Curve Status’...
  • Page 8 Plus takes you to the Control Menu. Choose a different menu by using the arrow keys. The Platinum Plus highlights the icons accordingly. Alternatively, you can press the indicated numeric key by each icon. For example, push the ‘3’ key to go directly to the History Menu.
  • Page 9 All history except ‘Alarms’ and ‘Table of Events’ erases for a new flock (see Management | New Flock). These two histories collect particularly important information regarding the past operation of the Platinum Plus. Test Menu The test menu screen...
  • Page 10 (outputs), and the particular sensors (temperature, humidity, etc.) you have. Also define the temperature sensors to use for growing and heat zones, as well as inform the Platinum Plus about your curtains and sidewall inlets. Switching Between Standard and Precision To change between the Platinum Plus’s two ventilation modes, standard...
  • Page 11 Platinum Plus Manual/Auto Switches he Platinum Plus can have up to 40 switches. Each switch usually controls one relay to turn one device on or off. Assign functions to each switch in the Install Menu. Initially none of the switches have a programmed function.
  • Page 12: General Description

    Poultry House Control General Description The Platinum Plus has two ventilation methods. The first is the Standard method; the second the Precision method. You may find the Standard method easier to learn at first, but the Precision method will give you more capability, and may be easier in the long run.
  • Page 13: Precision Ventilation Mode

    The Set Temperature is generally between heat and fan on/off temperatures. However, it can be higher or lower since it is only a reference. The Precision Mode Target Temperature is an actual goal the Platinum Plus tries to achieve. It is not simply a reference temperature.
  • Page 14: Standard & Precision, Example

    Poultry House Control Standard & Precision, Example Standard and Precision Ventilation Example Step 1 Current Conditions for Both Standard and Precision: 2 @ 36” Min Vent Fans 60 sec on, 240 off Target and Set Temperature: 80ºF Outside Temperature: 60ºF Inside Temperature: 80.5ºF Bird Heat is Balancing Outside Temperature Standard Mode Settings:...
  • Page 15: Other Devices

    Rotem's light dimmers. Optional scale modules allow you to connect bird and feed weighing systems. Here are some options you could add to your Platinum Plus: 1. Emergency Card with its own sensor and back up battery. 2. Normally Closed Switch Card.
  • Page 16 Poultry House Control 3. Winch and Curtain Card 4. Light Dimmers 5. Bird Scales 6. Feed Scales 7. Cross Fill Feed Monitor 8. Water Consumption 9. External Alarms 10. Communications 11. Curtains and baffles 12. Dwyer Magnehelic 13. Cane Switch 14.
  • Page 17: Standard Mode Programming Guide

    Platinum Plus Standard Mode Programming Guide Where do I start? Start with the Install Menu. Later programming steps can depend on earlier steps. You can use this chart as a guide. Standard Mode Programming Steps Step 1 … 6. Install Menu Comments: Ventilation Mode ►...
  • Page 18 (heat, fan), and some any number of times (feed, light). To duplicate ‘once only’ relays, use the ‘Same As…’ relay codes. By default, the Platinum Plus comes 1. Platinum Plus sensors with six temperature sensors typically are accurate to Install | preprogrammed.
  • Page 19 # relay codes, count Install | Help | Set enter the house dimensions the group as a single fan. Fan Air so the Platinum Plus can calculate Capacity wind chill temperature corrections. You can access system parameters as Some parameters may not ‘Set’...
  • Page 20 You may choose to turn on Minimum bird ages. Ventilation Ventilation Curve in Control, Control Timer Mode Menu. Then Platinum Plus will 2. Advanced growers may calculate intermediate cycle times. prefer to set min vent timers daily. If so, use only...
  • Page 21 Platinum Plus Standard Mode Programming Steps 1. Day: Growth Day Enter up to 20 Cool Pad settings. You can use the same Control | Cool 2. Start Time: Earliest time to turn on growth day several times, and water. increase water flow for higher 3.
  • Page 22 Poultry House Control Standard Mode Programming Steps can be active. Temp for operation. 3. From Temp: temperature above 3. Choose temperature which extra system can be active. sensors for extra systems in Install, Temperature 4. To Temp: temperature below Definition Menu. Assign a which extra system can be active.
  • Page 23: Standard Mode Example

    Standard Mode Example Let’s Start Here! First set up the Platinum Plus under the Install Menu. To enter the Install Menu, push the Menu button at the main screen. Select the Install Menu with the arrow keys and press Enter, or just press number key 6.
  • Page 24 √ √ Note: Under Help | Set you can reverse up to 5 relays, and select normal or power saving operation modes. By default, the Platinum Plus uses power saving mode for the relays to reduce heat inside the controller.
  • Page 25 Platinum Plus Analog Sensors The Platinum Plus regards temperature and Analog Sensors humidity sensors as ‘analog sensors’. These Channel Sensor sensors measure a continuous range rather than just Temperature Sensor 1 on or off. By default, it comes with 6 sensors which Temperature Sensor 2 are connected in order.
  • Page 26 Poultry House Control Temperature Definition The Temperature Definition Menu allows you to assign specific temperature sensors for various brood setups, and for the heater zones. You can also assign sensors to other pieces of equipment. However, in most cases leave these blank so that they operate according to average temperature.
  • Page 27: Control Menu

    Platinum Plus Control Menu The Control Menu is the place to enter actual operating settings for your poultry house. The first two menus in the control category are TEMP & TIMER SETTINGS and TEMPERATURE & HUMIDITY. Temperature and Timer Settings The TEMP &...
  • Page 28 2. Tunnel Exit Delay: upon reaching the tunnel off temperature, the Platinum Plus waits this length of time before actually leaving tunnel ventilation.
  • Page 29 Platinum Plus Temperature and Humidity The TEMPERATURE & HUMIDITY menu sets the desired SET temperature and low and high alarm temperatures by bird age. The humidity settings are not used at this time. Note: you can set zone alarms in Management | Alarm Setting (see page 86).
  • Page 30 The LIGHT Menu provides up to 50 on and off times. Note that all times are in 24 hour military format. The entry for day 1 ensures continuous light. This program assumes no light dimmer installed. The Platinum Plus can optionally control intensity settings with a slave light dimmer, including sunrise and sunset effects.
  • Page 31 Platinum Plus Feed The FEED menu can be programmed to correspond to the light table, or simply enter the first line only to allow the control hopper to run the feed system. Feed Start 00:00 00:00 Extra Systems The EXTRA SYSTEMS are a set of 4 controls you can use for various purposes. Use Extra System 1 for the Fail Safe system by programming it to be always on as shown.
  • Page 32 4. Min Vent Using Inlet?Tunnel: some producers do not have side inlets, but use tunnel inlets during minimum ventilation. 5. Emergency Pressure Delay (seconds): this is the length of time the Platinum Plus waits before taking emergency action in the event static pressure remains above the high pressure alarm setting.
  • Page 33: Precision Mode Programming Guide

    Platinum Plus Precision Mode Programming Guide Where do I start? Start with the Install Menu. Later programming steps can depend on earlier steps. You can use this chart as a guide. Precision Mode Programming Steps Step 1 … 6. Install Menu Comments: Ventilation Mode ►...
  • Page 34 ‘once only’ relays, use the ‘Same old one first, then program As…’ relay codes. the new one. By default, the Platinum Plus comes 1. Platinum Plus sensors with six temperature sensors typically are accurate to Install | preprogrammed.
  • Page 35 Install | Help | Set enter the house dimensions the group as a single fan. Fan Air so the Platinum Plus can calculate Capacity wind chill temperature corrections. 1. Tunnel and Exhaust fans appear 1. At each level mark desired...
  • Page 36 Zone for Target and Tunnel is settings. above their settings. Set minimum and maximum levels The Platinum Plus can not go based on bird age and the ventilation outside the minimum and Control | level table.
  • Page 37 Platinum Plus Precision Mode Programming Steps 1. Day: Growth Day Enter up to 20 Cool Pad settings. You can use the same Control | Cool 2. Start Time: Earliest time to turn on growth day several times, and water. increase water flow for higher 3.
  • Page 38 Poultry House Control Precision Mode Programming Steps the end & exit menu. Reenter table to see lines in correct position. Feed Control that matches the See Management, Alarm capability of the light table. Program Settings for feed alarms and Control | Feed feed times in the same way by growth automatic shut off of feed in day.
  • Page 39 Platinum Plus Precision Mode Programming Steps c) Transitional Tunnel all air sources open. Restore normal d) Incoming Air (Outside) operation using temperature for low/high Management, pressure. Alarm Reset Menu. e) Emergency Pressure Delay f) Curtain Position in Emergency g) Minimum Level limits for cross ventilation and tunnel ventilation.
  • Page 40: Precision Mode Example

    Precision Mode Example Let’s Start Here! The Platinum Plus main setup is under the Installation Menu. Program these in sequence. The purpose of the installation menus is to communicate to the Platinum Plus the type of equipment your house has. Install Menu The Setup Menu makes some basic operating mode choices.
  • Page 41 107 Lights Note: Under Help | Set you can reverse up to 5 relays, and select normal or power saving operation modes. By default, the Platinum Plus uses power saving mode for the relays to reduce heat inside the controller.
  • Page 42 Feed Count problem. Curtain Setup Curtain Setup tells the Platinum Plus how fast your curtains and side inlets move. It needs this information to properly calculate automatic inlet advance as well as inlet and curtain positions. Enter opening and closing...
  • Page 43 Platinum Plus Temperature Definition The Temperature Definition Menu allows you to assign specific temperature sensors for various brood setups, and for the heater zones. You can also assign sensors to particular pieces of equipment, but in most cases leave these blank so that they operate according to the default condition.
  • Page 44 Poultry House Control Ventilation Levels In precision mode the Platinum Plus provides up to 30 programmable ventilation levels. The usual way to program them is to start the first level with the least amount of air to be used. In the relay layout example above, we programmed 4 exhaust fans and 9 tunnel fans.
  • Page 45 Since the Platinum Plus can use any of these ventilation levels at the same target temperature, how does it pick the particular one it needs? The brief answer is that it doesn’t change ventilation levels instantly when there is a small difference from the target temperature.
  • Page 46: Precision Ventilation Example

    Poultry House Control The Platinum Plus has a separate tunnel entry temperature curve, as we will see further below. It is this tunnel entry temperature that determines when the Platinum Plus enters tunnel ventilation. This is the reason there is no differential on the first tunnel level.
  • Page 47 Platinum Plus Precision Ventilation Table, Example Exhaust Tunnel Fans Diff Fans 1 2 3 4 5 6 7 8 9 10 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●...
  • Page 48 In that event, the percent open settings become minimum settings. Then, once the side vents are at 100%, if pressure requires, the Platinum Plus will open the tunnel curtain to maintain the pressure setting. 24..30 Curtain Setup...
  • Page 49 Platinum Plus decreases one ventilation level to avoid overshooting. 7. Min Vent if Heater On Y/N: The Platinum Plus goes immediately to minimum ventilation if the average temperature reaches the heat temperature. This option allows...
  • Page 50 Poultry House Control 8. Non Brood Area Temperature: while in brood, the non-brood heaters operate to this temperature setting. 9. Radiant Low Differential From Heat: this sets the temperature below the heat temperature at which radiant brooders light. 10. Radiant High Differential From Low: this sets the temperature below the corresponding low level radiant heater at which the high level radiant heater lights.
  • Page 51 Platinum Plus Humidity Humidity Treatment Humidity treatment forces an Humidity Interval Duration increase in ventilation level for a Minutes Seconds minimum duration after an interval, if humidity is higher than set. It does not force a change in ventilation style from side or cross ventilation to tunnel ventilation.
  • Page 52 Poultry House Control Foggers Foggers Start Time End Time Target To % RH On Sec Off Sec Diff 10:00 18:00 15.0 Help | Set Parameters Temperature Band Humidity Band The fogger table allows several settings. In some cases you may interchange the use of the Cooling table and the Fogger table, since they both control evaporative cooling.
  • Page 53 Platinum Plus Stir Fan Settings Prog A Prog B Prog C Prog D Prog E √ √ √ √ √ √ Help | Set Parameters Param At End or Sensor Diff Target Diff On Time On Time Start 4.0ºF Param...
  • Page 54 The LIGHT Menu provides up to 50 on and off times. Note that all times are in 24 hour military format. The entry for day 1 ensures continuous light. This program assumes no light dimmer installed. The Platinum Plus can optionally control intensity settings with a slave light dimmer, including sunrise and sunset effects.
  • Page 55 3. Incoming Air Low Temp: outside temperature for low temperature pressure setting. 4. Incoming Air High Temp: outside temperature for high temperature pressure setting. 5. Emergency Pressure Delay (seconds): this is the length of time the Platinum Plus waits before taking emergency action in the event static pressure remains above the high pressure alarm setting.
  • Page 56 Poultry House Control Control Mode Control Mode House Mode FULL HOUSE Temperature Curve Min-Max Level by Days or by Time BY DAYS Select House Mode according to 1 brood, 2 brood, 3 brood or full house. Continue with Shared Menus on Page 57...
  • Page 57: Shared Menus Programming Guide

    Year in the flock number for 3. Use the ‘New Flock’ function to future reference. clear previous history data between flocks. Basic Alarms: The Platinum Plus provides numerous additional alarms Manage | Alarm 1. Global Alarm Delay: general in the advanced alarm menu. Setting delay before signaling on the alarm relay.
  • Page 58 1. Clear Alarm Relay or signaling Emergency Pressure and for current alarms Feed Overflow result in the Manage | Alarm Platinum Plus locking out the Reset 2. Restore normal operation after corresponding control an emergency pressure situation. features until you reset with 3.
  • Page 59 Platinum Plus Save Program Settings to Plug. Large Gold Plug holds up to 8 programs. Service | Save to Plug Read Saved Program settings from Large Gold Plug holds up to Plug 8 programs. Service | Read From Plug Program a U.S. Robotics Modem for use at the farm.
  • Page 60 Active alarms flash, or are in identify problems. red on a PC. History | Alarm Platinum Plus logs all significant Problems include such as yo- events. Review this regularly to yoing in and out of tunnel History | Table of identify problems.
  • Page 62: Detailed Description

    3. The communication option provides a means accidentally. To prevent this, the Platinum Plus to connect a personal computer locally or requires acknowledgement with the Enter key to remotely by modem.
  • Page 63: Installation

    Contrast adjustment for the display is located on the central processor card in the door Analog Output Card, RAOC-8 of the Platinum Plus. Open the door, remove the burnished cover and look in the upper right modes. corner area for a small square printed circuit You can program variable speed fans in card.
  • Page 64 The integrated static pressure sensor is connection. standard in each Platinum Plus controller. It connects by short air hoses to barbs protruding out through the left side of the controller. The inside hose should be installed inside the poultry building.
  • Page 65: Install Menu

    Plus is the mandatory alarm card. It is included 7. Baud Rate: Baud rate is a measure of the with each Platinum Plus to connect to your alarm communication speed for local or remote system. communications to a personal computer.
  • Page 66 Poultry House Control arrangement of temperature sensors is of tunnel ventilation. Select whether tunnel required. The Platinum Plus lists the ventilation applies to your facility. growing zones in Install | Temperature 13. History Resolution: The Platinum Plus Definition so you can assign specific collects a large amount of historical and sensors.
  • Page 67 +/- key again. and Black. A 2 humidity sensor shares the Red 3. The Platinum Plus shows the type of relay and Black terminals, but connects its white wire the cursor is on at the bottom left of the to the upper row connector labeled T9.
  • Page 68 Curtain Setup Enter the total opening and closing times of your natural curtains, tunnel curtain and side inlets in seconds. The Platinum Plus needs Scale card with optional key to enable this information to keep track of position, and to feed bin operation.
  • Page 69 0. individual temperature sensor. In the event such b. If the ventilation level is below tunnel, the a single sensor fails, the Platinum Plus differential temperature is relative to substitutes the current average temperature as Target temperature given in Control Menu shown on the standard display.
  • Page 70 ON and OFF times, in ventilation. For tunnel ventilation, enter rather than letting the Platinum Plus calculate the first tunnel level here. The controller the Off times, set this parameter to 0. The Off...
  • Page 71 6. Static Pressure settings specified in the Control Menu | Wind Gust Delay Time (seconds): the Platinum Plus waits this length of time to Temperature and Timer Settings just as do the normal heaters. Each high level respond to unexpected pressure changes.
  • Page 72 For example, 3 curtains at 20% each Start Fans: movement, the Platinum Plus turns off all totals to 60%, as does 2 curtains at 0% and exhaust and tunnel fans until the curtain one at 60%. reaches this position.
  • Page 73 Set Temp Change Reminder (Diff): This temperature which sets the point at which the Platinum Plus will emergency card takes over operation of its remind you to check your backup thermostats equipment. The emergency card has its when temperature settings change.
  • Page 74 Response: 3. Ventilation Levels temperature drops faster than this number Maximum Ventilation Levels: enter the last of degrees per minute, the Platinum Plus ventilation level programmed. You need not decreases ventilation one level even if use all 30 available levels.
  • Page 75 The adjustments unexpected pressure curtains (tunnel and natural curtains) open changes. Note that the Platinum Plus uses this amount in an emergency pressure event. zero delay when its actions result in h. Low Pressure Alarm Minimum Level pressure changes.
  • Page 76 Minimum Level To Enable Operation: that more than one curtain requires calibration minimum ventilation level to operate the simultaneously, the Platinum Plus calibrates cool cells. This applies to normal them one at a time in turn. operation of the Cool # and Cool Pad # b.
  • Page 77 Platinum Plus b. Total Feed Bin 1: this parameter alarms are available in the Management maintains the feed count for Silo 1. You Menu. can adjust this parameter for reclaim or any time you need to correct the Control Menu inventory.
  • Page 78 Temperature and Humidity, Standard Mode 1. Enter Set temperatures by growth day for up to 10 growth days. The Platinum Plus interpolates between the dates you enter. 2. If you start with a growth day greater than 1, the 1 day entered applies until then.
  • Page 79 Menu. towards the Happy Zone within one increase Devices assigned a timer run according to level delay, or the Platinum Plus will increase the timer when temperatures are above the device ventilation level to the next level. ON temperature, and are off below the OFF d.
  • Page 80 You can set several treatments level radiant heater. for a particular growth day at various humidity levels. The Platinum Plus sorts the table in order of Minimum/Maximum Level, Precision growth day, then humidity level when you exit from Mode the menu.
  • Page 81 Platinum Plus 7. To delete a line, simply set the day to 0. 5. Enter On seconds. The Cool outputs will not When you exit the menu, that line will operate at all if there is nothing in the On delete and subsequent lines move up.
  • Page 82 3. The End time is the time that the sunset for the To Time: latest time to allow stir fan light dimmer ends. The Platinum Plus calculates operation by program B (24 hour or backwards from the time you entered to find the military format applies).
  • Page 83 1. Each extra system as a Start Time, which is incur a delay; in such cases the Platinum Plus when it may turn on (if the other parameters anticipates the pressure change and pre-adjusts allow it to).
  • Page 84 Platinum Plus uses zero delay when its outside sensors selected to determine incoming air actions result in pressure changes. temperature, the Platinum Plus will use the Pressure b. Pressure During Tunnel (N-0/Y-1): select at Low Temperature setting below the Incoming Air...
  • Page 85 If this option is yes, then the minimum ventilation fans cycle on. The Platinum Plus opens the tunnel curtain default of 10 seconds is satisfactory in most enough to meet the target pressure.
  • Page 86: Management Menu

    Poultry House Control If you have installed load cells and Control Mode, Standard Mode connected feed bin scales to your Platinum Plus, it 1. House Mode: select whether the present will automatically maintain feed inventory, operating mode is Full House or a partial including delivery dates and feed consumption data.
  • Page 87 Shortage Alarm Delay (minutes): set the programmed as Feeder-1 Overtime or length of time to delay in the event of a water Feeder-2 Overtime the Platinum Plus will shortage. Default is 60 minutes. alarm after this delay. 8. Bird Scales Alarm b.
  • Page 88 Auxiliary Alarm Delay: you can set a 2. Lower Range: to eliminate weighing partial separate alarm delay for the auxiliary birds or double birds, the Platinum Plus rejects alarms. weights more than this amount in per cent 10. Circuit Breaker Alarm: below the current reference weight.
  • Page 89: History

    Bird Curve 2. Differential Below Target For Emergency: if The Platinum Plus has up to three the emergency card sensor is this amount below curves of the anticipated weight of pullet and the target temperature, the emergency card takes breeder flocks by bird age.
  • Page 90: Test

    If the relay number is in reverse video, each scale. the Platinum Plus in automatic mode has that relay If you select ‘Mixed’ weighing, the turned on. Underneath each relay number the...
  • Page 91: Service

    Service 1. down 5. up Temperature Calibration 2. up 6. up The Platinum Plus temperature sensors 3. down 7. up typically are within 0.5ºF. Routine calibration in air 4. up 8. up will likely result in reduced accuracy. To calibrate a...
  • Page 92: Index

    Poultry House Control Index advanced alarms, 77 decrease level delay, 74 Advanced Alarms, 87 digital sensor, 25, 42 air flow, 45 digital sensor card, 68 alarm card, 65 digital sensor test, 90 alarm history, 90 dimmer, 16, 62 alarm reset, 88 display, 62, 63 Alarm Setting, 77 electronic key, 62, 69...
  • Page 93 Platinum Plus House Number, 65 pressure calibration, 91 Humidity, 76 pressure test, 91 humidity calibration, 91 purge, 20, 29 humidity sensor, 67 radiant heater history, 90 humidity treatment, 51, 80 Radiant Heaters, 71, 74, 78 increase level delay, 74 read from plug, 91...
  • Page 94 Poultry House Control temperature definition, 26, 43, 69 vent by curtains, 20 time, 86 ventilation level, 44 timer, 30 Ventilation Levels, Precision, 69 timers, 79 versions, 62 transitional tunnel, 75 Warning, 2 tunnel entry temperature, 46 water and feed, 89 tunnel exit, 74 water calibration, 91 Tunnel Pressure, 84...