WARNING
Battery gives off flammable fumes that can
explode.
When starting from another machine,
make sure the machines do not touch.
This will prevent damage to engine
bearings and electrical circuits.
Always connect the battery POSITIVE (+)
to battery POSITIVE (+) and and the
battery NEGATIVE (–) to battery
NEGATWE (–).
Jump only with a battery source and with
the same voltage as the stalled machine.
This machine has a 12 volt starting system.
Use only equal voltage for lump starting.
Use higher voltage will damage the
electrical system.
Be sure the start switch is in the OFF
position BEFORE attaching the jumper
cables to the machine to be started.
Use of Jumper Cables
1. Move boost start machine near enough
to stalled machine for the jumper cables
to reach. But, do not allow machines to
touch.
2. Lower the bucket to the ground.
Move all controls to HOLD. Stop the
engine on boost machine.
3. On stalled machine, turn the start switch
key to OFF. Turn of all accessories.
OPERATION

2-5 JUMPER CABLE STARTING

2 – 13
4. Connect POSITIVE (+) jumper cable (red)
P O S I T I V E ( + ) c a b l e t e r m i n a l o f
discharged battery.
Do not allow positive (+) cable clamp to
touch any metal other than battery
terminals.
5. Connect POSITIVE (+) jumper cable (red)
POSITIVE (+) cable terminal of boost
battery.
6. Connect one end of NEGATIVE (–)
jumper cable (black) to the
NEGATIVE (–) boost battery terminal.
7. Make final connection of NEGATIVE (–)
cable to frame of the stapled machine (not
NEGATIVE (–) post) away from battery
or fuel line.
8. Start the engine on the boost machine.
9. Wait a minimum of two minutes for the
batteries in the stalled machine to partially
charge.
10. Attempt to start the stalled engine.
Refer to section on Engine Starting.
11. Immediately after starting the engine,
disconnect the jumper cables in reverse
order.
12. Conclude failure analysis on starting/
charging system of stalled machine as
required now that engine is running and
charging system is in operation.