9903 MOTOR TYPE Selects the motor type.
AM
PMSM
9904 MOTOR CTRL
MODE
VECTOR:
SPEED
VECTOR:
TORQ
SCALAR:
FREQ
Description
Cannot be changed while the drive is running.
Asynchronous motor. Three-phase AC voltage-supplied
induction motor with squirrel cage rotor.
Permanent magnet motor. Three-phase AC voltage-
supplied synchronous motor with permanent magnet rotor
and sinusoidal back emf voltage.
Selects the motor control mode.
Sensorless vector control mode.
Reference 1 = speed reference in rpm.
Reference 2 = speed reference in percent. 100% is the
absolute maximum speed, equal to the value of parameter
2002 MAXIMUM SPEED
absolute value of the minimum speed is greater than the
maximum speed value).
Vector control mode.
Reference 1 = speed reference in rpm.
Reference 2 = torque reference in percent. 100% equals
nominal torque.
Scalar control mode.
Reference 1 = frequency reference in Hz.
Reference 2 = frequency reference in percent. 100% is the
absolute maximum frequency, equal to the value of
parameter
2008 MAXIMUM FREQ
FREQ
if the absolute value of the minimum speed is greater
than the maximum speed value).
(or
2001 MINIMUM SPEED
(or
2007 MINIMUM
Def/FbEq
AM
1
2
SCALAR:
FREQ
1
if the
2
3