Download Print this page

Adjustments; Checking; Inform Building Owner / Operator Of The Following Items; Troubleshooting - Optex OA-FLEX T User Manual

Advertisement

ADJUSTMENTS

1
Area angle adjustment
1-1.Area depth angle adjustment
When adjusting the 2nd row close to the door, see dipswitch 16 in Dipswitch settings table and REFERENCE for
the easier adjustment.
Shallow
-8°
+8°
NOTE
Make sure that the detection area does not overlap with the door / header, and there is no highly
reflecting object near the detection area otherwise ghosting / signal saturation may occur.
1-2.Area width angle adjustment
The angle of the detection area can both be moved 7° either left or right in 2 steps.
3.5°×2
3.5°×2
Left
2
Area width adjustment
Adjust the detection area width with the adjustment screws.
1
2
Left
eliminated
NOTE
When setting the detection area width, make sure to turn the adjustment screws until it clicks.
1 2
cannot be eliminated separately, neither can
3
Dipswitch settings
After changing the dipswitch settings,
make sure to push the function switch for 2 seconds.
Dipswitch settings table
Function
Low
High
Dipswitch
Sensitivity
1
1
Dipswitch
2
30sec.
60sec.
Presence timer
Dipswitch
2
3
2
3
Dipswitch
A
B
4
Frequency
Dipswitch
4
5
4
5
Dipswitch
6rows
5rows
6
Row adjustment
Dipswitch
6 7
6 7
7
OFF
ON
Dipswitch
Immunity
8
8
N.O.
N.C.
Dipswitch
Activation output
9
9
Enable
Disable
Dipswitch
Self Monitoring
10
10
10
High
Low
Dipswitch
Safety output
11
11
11
High
Low
Dipswitch
Safety input
12
12
12
Dipswitch
13
OFF
ON
Dipswitch
Simultaneous
output
14
14
14
OFF
ON
BLUEZONE
Dipswitch
15
(1st row)
15
15
OFF
ON
Dipswitch
Installation mode
16
16
16
Deep Shallow
Deep
[m(feet,inch)]
2.0(6 ' 7 " )
2.0(6 ' 7 " )
2.5(8 ' 2 " )
2.5(8 ' 2 " )
3.0
2.0
1.0
0
(9 ' 10 " )
(6 ' 7 " )
(3 ' 3 " )
Left
[m(feet,inch)]
2.0(6 ' 7 " )
2.0(6 ' 7 " )
Right
2.5(8 ' 2 " )
2.5(8 ' 2 " )
2.0
1.0
0
1.0
(6 ' 7 " )
(3 ' 3 " )
(3 ' 3 " )
Front view
7
8
Right
eliminated
2.0(6 ' 7 " )
2.5(8 ' 2 " )
2.0
1.0
0
(6 ' 7 " )
(3 ' 3 " )
1
2
3 4 5
7 8
push 2 seconds
Setting
Comment
Set the sensitivity according to the mounting
height.
1
The presence timer is applied to
BLUEZONE(1st row), 2nd row and 3rd row.
180sec.
600sec.
The presence timer can be selected
from 4 settings.
3
3
2
3
2
When using more than one sensor close
C
D
to each other, set the frequency different
for each sensor.
5
4
5
4
5
Set the depth rows with dipswitches 6 and 7.
4rows
3rows
6 7
6 7
Set dipswitch 8 to "ON" when the sensor
operates by itself (Ghosting).
8
Dipswitch 9 is for the Activation output
to door controller.
9
When the door remains open and the
operation indicator shows Fast/Slow Green
Blinking, refer to TROUBLESHOOTING.
If the door still remains open, set dipswitch 10
to "Disable".To comply with EN 16005, set
dipswitch 10 to "Enable".
Dipswitch 11 is for the Safety output
(to door controller).
Dipswitch 12 is for the Safety input
(from door controller).
N/A
When Dipswitch 14 is set to "ON", both
Activation & Safety output will operate
simultaneously regardless of detection area.
But only Safety output will respond back
with Safety output when it receives
Safety input.
When dipswitch 15 is set to "ON", the
BLUEZONE (1st row) is active and looks
through the threshold.
Set dipswitch 16 to
"ON"
row. During the installation mode only the
2nd row remains active and the operation
indicator shows yellow. After setting the row
switch dipswitch 16 "OFF".

CHECKING

Check the operation according to the chart below.
Entry
Image
[m(feet,inch)]
Operation
indicator
9
N.O.
N.C.
9
Activation
2.0
1.0
0
-1.0
output
(6 ' 7 " )
(3 ' 3 " )
(3 ' 3 " )
9
N.O.
9
N.C.
11
High
11
Low
Safety
output
11
High
Right
11
Low
[m(feet,inch)]
NOTE
*
When dipswitch 15 is set to "ON".
:

INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS

1.0
0
1.0
2.0
(3 ' 3 " )
(3 ' 3 " )
(6 ' 7 " )
WARNING
1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth.(Do not use any cleaner / solvent.)
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
4. When the operation indicator blinks Green, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the detection window.
[m(feet,inch)]
1. When turning the power ON, always walk-test the detection area to ensure the proper operation.
NOTE
2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)

TROUBLESHOOTING

1.0
2.0
Operation
Door operation
(3 ' 3 " )
(6 ' 7 " )
6
7
8
Door does not
open when a
person enters
the detection
area.
Door opens
when no one
is in the
detection area.
(Ghosting)
Door remains
open
Proper
operation
* : After changing the dipswitch settings, make sure to push the function switch for 2 seconds.
REFERENCE
Area depth adjustment with INFRARED FINDER (Separately available)
1.Turn the depth angle adjustment screw to the right (Deep) to place the
detection area most away from the door.
2. Set INFRARED FINDER sensitivity to "H" (High) and place it on the floor as shown below.
3. Turn the depth angle adjustment screw to the left (Shallow) until the emitting area is placed at the position where
INFRARED FINDER is in the low detection status (Slow Red Blinking).
to adjust the 2nd
Manufacturer
OPTEX Co.,LTD.
5-8-12 Ogoto Otsu 520-0101, Japan
TEL.: +81(0)77 579 8700
WEBSITE: www.optex.co.jp/as/eng/index.html
Outside of
Entry to
Power off
detection area
4th to 6th row
Green
Orange
None
ON
OFF
OFF
14
OFF
ON
OFF
OFF
OFF
14
ON
ON
OFF
OFF
14
OFF
ON
OFF
OFF
14
ON
ON
Possible cause
indicator
None
Wrong power supply voltage.
Wrong wiring or connection failure.
Unstable Wrong detection area positioning.
Sensitivity is too low.
Short presence timer.
Dirty detection window.
Proper
Wrong wiring or connection failure.
Objects that move or emit light in
Unstable
the detection area.
The detection area overlaps with that
of another sensor.
Waterdrops on the detection window.
The detection area overlaps with
the door/header.
Sensitivity is too high.
Others
Proper
Wrong setting of dipswitches .
Sudden change in the detection area.
Proper
Wrong wiring or connection failure.
Installation mode is set to " ON ".
Yellow
Fast
Sensitivity is too low.
Green
Dirty detection window.
Blinking
Sensor failure.
Slow
Signal saturation. (2nd and/or 3rd row)
Green
Blinking
The detection area overlaps with
the door/header.
Red &
Setting error.
Green
Blinking
Slow
Signal saturation.
Green
(4th, 5th, 6th row and/or BLUEZONE)
Blinking
Detection area
Detection area
European Subsidiary
OPTEX Technologies B.V.
Henricuskade 17, 2497 NB The Hague, The Netherlands
FAX.: +81(0)77 579 7030
TEL.: +31(0)70 419 41 00
E-MAIL: info@optex.eu
Entry to
Entry to
Entry to
BLUEZONE
3rd row
2nd row
(*)
Red
Red Blinking
Blue
OFF
ON
ON
OFF
ON
OFF
ON
OFF
Possible countermeasures
Set to the stated voltage.
Check the wires and connector.
Check ADJUSTMENTS 1, 2.(*)
Set the sensitivity higher.(*)
Set the presence timer longer. (*)
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Check the wires and connector.
Remove the objects.
Check ADJUSTMENTS 3 dipswitch 4,5.(*)
Use the rain-cover. (Separately available)
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Install in a place keeping the waterdrops off.
Adjust the detection area to "Deep" (Outside).
Set the sensitivity lower.(*)
Set dipswitch 8 to "ON".(*)
Check ADJUSTMENTS 3 dipswitch 9,11,12.(*)
Check ADJUSTMENTS 3 dipswitch 1 to 3.(*)
If the problem still persists, hard-reset the sensor.
(Turn the power OFF and ON again.)
Check the wires and connector.
Set dipswitch 16 to " OFF ".(*)
Set the sensitivity higher.(*)
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Contact your installer or service engineer.
Remove highly reflecting objects from the
detection area. Lower the sensitivity.(*)
Change the area depth angle.
Adjust the detection area to "Deep" (Outside).
After changing the dipswitch settings, make
sure to push the function switch for 2 seconds.
Remove highly reflecting objects from the
detection area. Lower the sensitivity.(*)
Change the area depth angle.
INFRARED FINDER
FAX.: +31(0)70 317 73 21
WEBSITE: www.optex.eu

Advertisement

loading