7.1

Components

The refrigerant circuit of the roof air conditioner consists of five main components
(fig. 1, page 3):
• Compressor (1)
The compressor draws in the R407c refrigerant used and compresses it. This
raises the pressure and therefore the temperature of the refrigerant.
• Condenser (2)
The built-in liquefier works like a cooler or heat exchanger. The air flowing past
absorbs the heat and the hot refrigerant gas cools down and becomes liquid.
• Evaporator (3)
The evaporators cool down and dehumidify the air flowing past them. The
refrigerant absorbs the heat and vaporises.
• Blower (4)
A blower distributes the cooled air within the vehicle through an air outlet unit.
• Solenoid valve (5)
The solenoid valve allows the cooling cycle to be reversed and the air feeding in
to be heated.