Dometic FRESHLIGHT FL1600 Installation Manual

Dometic FRESHLIGHT FL1600 Installation Manual

Air conditioning roof unit
Hide thumbs Also See for FRESHLIGHT FL1600:

Advertisement

Quick Links

AIR CONDITIONERS
FL1600, FL2200
Air conditioning roof unit
EN
Installation Manual. . . . . . . . . . . . . . . . . . . . . 3
Dachklimaanlage
DE
Montageanleitung. . . . . . . . . . . . . . . . . . . .22
Climatiseur de toit
FR
Instructions de montage . . . . . . . . . . . . . . .42
Aire acondicionado de techo
ES
Instrucciones de montaje . . . . . . . . . . . . . . 61
Ar condicionado para tejadilho
PT
Instruções de montagem . . . . . . . . . . . . . . 81
Climatizzatore a tetto
IT
Indicazioni di montaggio . . . . . . . . . . . . . 101
Airconditioning voor dakinbouw
NL
Montagehandleiding . . . . . . . . . . . . . . . . 120
Klimaanlæg til tagmontering
DA
Monteringsvejledning. . . . . . . . . . . . . . . . 139
Takmonterad klimatanläggning
SV
Monteringsanvisning. . . . . . . . . . . . . . . . . 158
Takmontert klimaanlegg
NO
Monteringsanvisning. . . . . . . . . . . . . . . . . 176
FRESHLIGHT
Kattooilmastointilaitteisto
FI
Asennusohje . . . . . . . . . . . . . . . . . . . . . . . 194
Накрышный кондиционер
RU
Инструкция по монтажу. . . . . . . . . . . . . . 212
Klimatyzator dachowy
PL
Instrukcja montażu . . . . . . . . . . . . . . . . . . 233
Strešné klimatizačné zariadenie
SK
Návod na montáž . . . . . . . . . . . . . . . . . . . 252
Střešní klimatizace
CS
Návod k montáži . . . . . . . . . . . . . . . . . . . . 271
Tetőklíma-berendezés
HU
Szerelési útmutató . . . . . . . . . . . . . . . . . . 289

Advertisement

Table of Contents
loading

Summary of Contents for Dometic FRESHLIGHT FL1600

  • Page 1 AIR CONDITIONERS FRESHLIGHT Kattooilmastointilaitteisto Asennusohje ..... . . 194 Накрышный кондиционер Инструкция по монтажу....212 Klimatyzator dachowy Instrukcja montażu .
  • Page 3: Table Of Contents

    FreshLight Please read this instruction manual carefully before installation and first use, and store it in a safe place. If you pass on the product to another person, hand over this instruction manual along with it. Table of contents Explanation of symbols ......... . .4 Safety and installation instructions .
  • Page 4: Explanation Of Symbols

    Explanation of symbols FreshLight Explanation of symbols DANGER! Safety instruction: Failure to observe this instruction will cause fatal or serious injury. WARNING! Safety instruction: Failure to observe this instruction can cause fatal or serious injury. CAUTION! Safety instruction: Failure to observe this instruction can lead to injury. NOTICE! Failure to observe this instruction can cause material damage and impair the function of the product.
  • Page 5 FreshLight Safety and installation instructions Handling the device WARNING! • Installation and repair of the roof air conditioner may only be carried out by qualified personnel who are familiar with the risks involved and the relevant regulations. Inadequate repairs may cause serious hazards.
  • Page 6: Target Group For This Instruction Manual

    Target group for this instruction manual FreshLight NOTE • Please ask your vehicle manufacturer if a technical inspection is required after fitting an air conditioner and whether the height entered in the vehicle documents needs to be altered (increased height 210 mm).
  • Page 7: Scope Of Delivery

    Available as accessories (not included in the scope of delivery): Part designation Reference no. DC extension kit DC-Kit2 9100300001 DC extension kit DC-Kit3 9100300002 DC extension kit DC-Kit5 9100300073 NOTE The DC extension kit (accessory) allows the Dometic FreshLight roof air conditioner to be used while in motion.
  • Page 8: Intended Use

    You can find additional information on roof air conditioners in the oper- ating manual, such as the technical description or the controls. Labels Labels are attached to the Dometic FreshLight roof air conditioners. These labels pro- vide the user and fitter with information on specifications of the device.
  • Page 9: Installation

    FreshLight Installation Installation CAUTION! Beware of injury The roof air conditioner may only be installed by qualified personnel from a specialist company. The following information is intended for technicians who are familiar with the guidelines and safety precautions to be applied. Note on installation Read this installation manual completely before installing the roof air conditioner.
  • Page 10 Installation FreshLight Note on transport • Always have someone help you carry the roof air conditioner. • Always lift the roof air conditioner to move it and never drag it over the roof (fig. 2 A). • Do not use the rear ventilation slots to lift it (fig. 2 B). Note on installation location •...
  • Page 11 FreshLight Installation Note on electrical system • Only a qualified electrician should connect the roof air conditioner to the electrical power. • Check that the voltage specification on the type plate is the same as that of the power supply. •...
  • Page 12 Installation FreshLight See fig. 5 ➤ Before installation, check whether the roof hole needs reinforcing. ➤ Remove the foam according to the width of your reinforcing rails (not in scope of delivery) (A). ➤ Fit the reinforcing rails (B). Installing in a roof hatch opening already provided NOTE •...
  • Page 13 FreshLight Installation Laying the connecting cables DANGER! Danger of electrocution Make sure there is no voltage at electrically operated components before carrying out work on them! The roof air conditioner must be connected to an electric circuit which is able to supply the required current (see chapter “Technical data”...
  • Page 14 Installation FreshLight Attaching the roof air conditioner See fig. a ➤ Mount the fastening bracket with the two long fastening screws. Start with the two fastening brackets on the outside. See fig. b NOTICE! Risk of damage Tighten to the specified torque. ➤...
  • Page 15 FreshLight Installation Connecting the air outlet unit with the roof air conditioner See fig. d ➤ Remove the premounted filter covers (1). ➤ Remove the premounted air filter (2). Fitting the seals See fig. e ➤ Fit the seals (1). Determine the thickness by referring to the following table: Ceiling thickness Seal thickness...
  • Page 16 Installation FreshLight Installing the air outlet unit See fig. g ➤ Attach the air outlet unit to the (1) fastening brackets using the short fastening screws. ➤ Insert the caps (2) in the holes over the fastening screws. See fig. h ➤...
  • Page 17: Troubleshooting

    FreshLight Troubleshooting Troubleshooting Problem Cause Remedy Roof air Icing sensor has tripped. Outer temperature is too low or all air conditioner nozzles are closed. constantly switches itself off. ➤ Set the roof air conditioner to No cooling The roof air conditioner is not set to capacity cooling.
  • Page 18: Disposal

    Disposal FreshLight Problem Cause Remedy ➤ Remove any leaves and other dirt Low air output The air intake section is clogged up. from the ventilation grilles of the roof air conditioner. ➤ Contact an authorised workshop. The blower is defective. ➤...
  • Page 19 • Keep noise levels down to reduce noise pollution. For more information on correct dismantling of our products please refer to the recycling handbooks at www.dometic.com. ➤ Place the packaging material in the appropriate recycling waste bins wherever possible.
  • Page 20: Technical Data

    Technical data FreshLight Technical data Dometic FreshLight 1600 2200 Ref. no.: 9102900207 9102900165 Cooling capacity based on ISO 5151: 1500 W 2050 W Heating capacity: max. 2050 W max. 2700 W Rated input voltage: 230 Vw/50 Hz Power consumption in cooling mode: 2.7 A...
  • Page 21 FreshLight Technical data Dometic FreshLight 1600 2200 Weight: approx. 40 kg approx. 42 kg Inspection/certification: Contains fluorinated greenhouse gases Hermetically sealed equipment...

This manual is also suitable for:

Freshlight fl2200

Table of Contents