Technical Information - Panasonic NR-BW415XS Service Manual

Table of Contents

Advertisement

NR-BW415 / NR-BW465

13. TECHNICAL INFORMATION

NR-BW415VN, VW / NR-BW465VN, VW / NR-BW415XS / NR-BW465XS
• Lead wire (Pink color) open
Effective from : Refer to page no. 28
Serial No. start : Refer to page no. 28
Countries
: Refer to page no. 28
Type
: Countermeasure taken
Recommend : At occurrence
1. Symptom of the problem
The defrost function didn't operated caused by Lead wire open.
So the unit didn't cool.
2. Cause
1. Some conductor of lead wire (Pink color) is breaking of wire by
2. When defrost function would operate, would start sparking
between conductors in condition of water condensation in
plastic bag.
3. Completely breaking of lead wire. (Pink color)
3. Detail of countermeasure / TI No. : REF 12-07
1) Change new lead wire (Pink) with new connector 1 pcs.
2) Connect by U-Connector 1 pcs.
3) Cover by silicone tape 1 pcs.
4) Replace new one plastic bag & cable tie per 1 pcs.
5) Refer to detail of KIT as below.
4. Description part addition / compatibility
Status
Ref.
New
1
2
3
4
5
Conditions
Countermeasure Kit to old unit
Part Name
Countermeasure kit
Lead wire (Pink color)
U-Connector
Silicone tape
Plastic bag
Cable tie
Description
Q'ty
CNRBG17006KT
1 Kit
N/A
1 Pcs.
CNR76-316850
1 Pcs.
CNR79-314920
1 Pcs.
CNRAG-164170
1 Pcs.
CNR39-220010
1 Pcs.
Parts compatibility
OK
- 25 -