10. TROUBLESHOOTING GUIDE

10.1 Not cool at all [ Both PC & FC (compressor does not operate) ]
1
Does room light turn on?
Pushing PC door switch and room light turns
2
off, and after release PC door switch, does
room light turn on?
To start self diagnosing function by opening
3
PC door and FC door and pushing
"Quick Freezing" SW for 5 seconds.
Does "ECONAVI LED" and "Quick Freezing"
4
blink?
Does the "ECONAVI LED" turn on and
5
"Quick Freezing" blinking?
Does the "ECONAVI LED" turn off and
6
"Quick Freezing" blink?
Does the "ECONAVI LED" turn off, "Quick
7
Freezing" turn off and "Freezer Control" LED
"MAX" blink?
Does the "ECONAVI LED" turn off, "Quick
8
Freezing" turn off and "Freezer Control" LED
"MIN" blink?
NO
YES
NO
YES
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
Check power supply.
Ex. Connect power cord in inlet
Ex. Check ELCB
• Defect of over load relay.
Ex. Does fuse blow?
• Check control PCB.
Ex. Does fuse blow?
Ex. Defect of IC (IC205), Diode (BD201), etc.
Defect of control PCB.
• Defect PC door switch.
Defect of control PCB.
• Communication error between IC1 & IC201
Defect of control PCB.
• Abnormal connecting of compressor.
• Compressor lock.
• Chock.
• Leakage.
• Droping voltage of power supply.
• Rising voltage of power supply.
Break FC thermistor.
• Poor connection between FC thermistor and
PCB.
Gas leakage at high pressure side.
• Poor compression.
• Defect of control PCB.
• Gas leakage at low pressure side.
• Defect of control PCB.
• Faulty compressor motor.
• Compressor lock.
- 16 -