Econavi Operation Doesn't Work (Pc/Fc/Ic Cooling Condition Is Normal) - Panasonic NR-BW415XS Service Manual

Table of Contents

Advertisement

NR-BW415 / NR-BW465
10.3 ECONAVI operation doesn't work
(PC/FC/IC cooling condition is normal)
Is the temperature control set to
1
{ 2 (Middle) } for FC?
Does LED indicate "ECONAVI LED" or
2
"Quick Freezing" or "Freezer Control
LED" lighting and blinking?
Does "Quick Freezing" function
3
operating?
4
Is the FC temperature -17 °C or below?
Does "Freezer Control LED" turn on
5
MAX blink?
Press "Freezer" button 5 seconds.
6
It is normal (keep a wait and see)
7
If it meets the above condition, ECONAVI operation begins and the lamp lights when the door opening and closing
is not done for 3 hours. (with some exceptions)
Test of ECONAVI operation. (Quickly confirms for turning on the ECONAVI light)
NO
YES
YES
NO
YES
NO
NO
YES
YES
NO
Unlit (ECONAVI)
Turn off setting
FC set to { 2 (Middle) }
Some LED indicator is displayed on
the notice indicator area, ECONAVI
will not operate.
Quick Freezing is operating,
ECONAVI will not operate.
The internal temperature is high,
ECONAVI will not operate.
Faulty operation panel PCB.
Faulty control PCB.
• Faulty operation panel PCB.