NR-BW415 / NR-BW465
10.3 ECONAVI operation doesn't work
(PC/FC/IC cooling condition is normal)
Is the temperature control set to
1
{ 2 (Middle) } for FC?
Does LED indicate "ECONAVI LED" or
2
"Quick Freezing" or "Freezer Control
LED" lighting and blinking?
Does "Quick Freezing" function
3
operating?
4
Is the FC temperature -17 °C or below?
Does "Freezer Control LED" turn on
5
MAX blink?
Press "Freezer" button 5 seconds.
6
It is normal (keep a wait and see)
7
If it meets the above condition, ECONAVI operation begins and the lamp lights when the door opening and closing
is not done for 3 hours. (with some exceptions)
Test of ECONAVI operation. (Quickly confirms for turning on the ECONAVI light)
NO
YES
YES
NO
YES
NO
NO
YES
YES
NO
Unlit (ECONAVI)
Turn off setting
•
FC set to { 2 (Middle) }
•
Some LED indicator is displayed on
the notice indicator area, ECONAVI
will not operate.
•
Quick Freezing is operating,
ECONAVI will not operate.
•
The internal temperature is high,
ECONAVI will not operate.
•
Faulty operation panel PCB.
•
Faulty control PCB.
• Faulty operation panel PCB.
- 19 -