NR-BW415 / NR-BW465

6. SELF DIAGNOSING FUNCTION

6.1 Inverter : X Series

Start mode
1. Plug in.
2. Open PC Door.
3. Push button QUICK (1)
within 30 sec.
4. At Freezer level "MIN" and "MED" blinking (No. 1) and "ECONAVI" light on (No. 2).
5. After 1 minute ECONAVI lamp will be blinking and Freezer level off.
6. Check sensor by use finger close at sensor (No. 3).
7. Freezer level and ECONAVI be recovery (Process No. 4).
8. Self diagnosis from items table as below when have some abnormal.
FREEZER CONTROL
QUICK FREEZING
Self diagnosis / new BW series
FCC
DFC
ATC
FC FAN MOTOR
DEFROST HEATER
INV COMP
PCB
HC LEAK (HIGH PRESSURE)
HC LEAK (LOW PRESSURE)
ILLUMINANCE SENSOR
Manual defrost mode
Before check have to clear mode as normal.
1. Open PC Door.
2. Push button FREEZER (2)
3. Check Comp. will not operate.
4. Or push QUICK button / QUICK FREEZING LED will blinking.
FREEZER (2)
BUTTON (2)
BUTTON (1)
ECONAVI
LED
QUICK (1)
QUICK (1) / process no. 1 ~ 3 must complete
QUICK
LED
MAX
FREEZER (2)
FREEZER (2) [Hold 1 sec. over].
- 11 -
NO. 2
NO. 1
NO. 3
Lighting
Blinking
FC CONTROL LED
MED
MIN
Off