H. Replacing the Circuit Breaker (Not present on RSL5 or RSL5C)
CAUTION: Unplug the vacuum cleaner before servicing.
1. Remove nozzle cover as shown on page 10, II. Maintenance, B. Removing Nozzle Cover
2. Remove leads from circuit breaker. (Fig. A and B)
3. Squeeze the tabs on the side of the circuit breaker with needlenose pliers and push it out through the
nozzle. (Fig. C)
4. Push new breaker into nozzle from the outside until it clicks. (Fig. D)
5. Reattach leads.
6. Reassemble.
Fig. A
Fig. C
II. Maintenance
Fig. B
Fig. D