A Connecting the refrigerant pipe
1
Remove the pinch pipe on the pipes and connect the assembly pipes to each pipe, tightening the nuts, first
manually and then with a torque wrench, a spanner applying the following torque.
Outer Diameter
mm
6.35
9.52
12.7
15.88
Note
Must apply refrigerant oil on the flaring area to prevent a leak.
2
Be sure that there must be no crack or kink on the bended area.
AM
FNLD
Drain hose connection port
Gas refrigerant port
Liquid refrigerant
port
AM
MNMD
/ AM
Gas refrigerant port
Liquid refrigerant port