TEST SETUP & ADJUSTMENT
ii)
Select "CHANNEL BLOCK 1" and set the following parameter:
CHANNEL BLOCK
Other Channel Blocks (Channel Block 2, 3, 4) set to "EXCLUDED"
B) Reverse setting:
STEP 4
i)
Press the (USER DEFINED KEY) and set the following parameters:
FREQ BAND
OFFSET
DUPLEX SPACING
REVERSE
ii)
Select "CHANNEL BLOCK 2" and set the following parameter:
CHANNEL BLOCK
Other Channel Blocks (Channel Block 1, 3, 4) set to "EXCLUDED"
For B Band (400 - 430 MHz)
A) Normal setting:
STEP 4
i)
Press the (USER DEFINED KEY) and set the following parameters:
FREQ BAND
OFFSET
DUPLEX SPACING
REVERSE
ii)
Select "CHANNEL BLOCK 3" and set the following parameter:
CHANNEL BLOCK
Other Channel Blocks (Channel Block 1, 2, 4) set to "EXCLUDED"
B) Reverse setting:
STEP 4
i)
Press the (USER DEFINED KEY) and set the following parameters:
FREQ BAND
OFFSET
DUPLEX SPACING
REVERSE
ii)
Select "CHANNEL BLOCK 4" and set the following parameter:
CHANNEL BLOCK
Other Channel Blocks (Channel Block 1, 2, 3) set to "EXCLUDED"
CM5000 Mobile Repeater/Gateway - Basic Service Manual
INCLUDED
3
3
0
1
INCLUDED
4
3
0
0
INCLUDED
4
3
0
1
INCLUDED
31