Baxi LUNA3COMFORT Installers And Users Instructions page 6

High efficiency wall-mounted gas-fired boilers
Table of Contents

Advertisement

3.4 ROOM AND DOMESTIC HOT WATER (D.H.W.) TEMPERATURE ADJUSTMENT
The room (
) and D.H.W. (
When the burner is lighted the display shows the symbol ( ) as described in section 3.1.
During a CH mode, the display shows a CH (
During a temperature regulation, the display shows "AMB".
DOMESTIC HOT WATER (D.H.W.)
During a D.H.W. request, the display shows a D.H.W. (
During a temperature regulation, the display shows "HW SP".
NOTE:
if an external water tank is connected to the gas boiler, during a domestic hot water request, the display shows a
(
) symbol and the room temperature value (°C).
3.4.1. Remote control installed on the boiler front panel
If the remote control is installed on the boiler front panel, the
The display shows the room temperature.
SETTING THE DATE-TIME
Press the IP button: the display shows (briefly) the message PROGR and the time starts flashing.
Note: If no button is pressed the function ends automatically after approx. 1 minute.
+/-
+/-
+/-
(1...7 corresponding to Monday...Sunday);
Press the IP button to exit DATE-TIME setting.
3.6 PROGRAMMING HEATING MODE OPERATION TIMES
To enable the function, press the
Time period programming allows the setting of boiler automatic operation in heating mode in fixed time slots and
on fixed days of the week.
Boiler operation settings can be made for single days or groups of consecutive days.
3.6.1. Single days
Four time bands (4 boiler activation and deactivation periods in heating mode even with different times from day to
day) are available for every day selected, as shown in the following table:
INSTRUCTIONS PERTAINING TO THE USER
) temperature adjustment are carried out by pressing the relative +/- buttons (figure 1).
) symbol and the room temperature value (°C).
) symbol and the room temperature value (°C).
3.5 PROGRAMMING (PROGR)
to set the hour;
to set the minutes;
to set the day of the week "Day"
button (the display shows the
+/-
buttons regulate the Central Heating flow temperature.
symbol)