This type of ducting allows to disengage exhaust flue gases both outside the building and into single flue ducts.
Comburant air may be drawn in at a different site from where the flue terminal is located.
The splitting kit consists of a flue duct adaptor (100/80) and of an air duct adaptor.
For the air duct adaptor fit the screws and seals previously removed from the cap.
The restrictor must be removed in the following cases
Air suction
Boiler
model
0 ÷ 4
4 ÷ 15
240 Fi
1.240 Fi
15 ÷ 25
25 ÷ 40
0 ÷ 2
310 Fi
2 ÷ 8
1.310 Fi
8 ÷ 25
Note: The first 90° bend is not included in the maximum available length.
The 90° bend allows to connect the boiler to flue-air ducting regardless of direction as it can be rotated by 360°. It can
moreover be used as a supplementary bend to be coupled with the duct or with a 45° bend.
Split flue air control adjustment
The adjustment of this control is required
to optimise performance and combustion
parameters. The air suction coupling can
be rotated to adjust excess air according
to the total length of the flue and intake
ducts for the combustion air.
Turn this control to increase or decrease
excess combustion air (figure 9):
To improve optimisation a combustion
product analyser can be used to measure
the CO
contents of the flue at maximum
2
heat output, gradually adjusting air to
obtain the CO
reading in the table below,
2
if the analysis shows a lower value.
To properly install this device, also refer
to the technical data accompanying the
fitting.
Flue
coupling
RESTRICTOR
A
position
3
Yes
1
2
No
3
1
2
No
3
Flue duct adaptor
CO2 %
G31
6,4
7,3
7,4
8,4
Seal
Air suction coupling
adjust
Index
Opening
18
Figure 9
925.220.4 - EN