Number Of Can Nodes; Ni 9853 Hardware Overview - National Instruments NI 9853 Getting Started Manual

2-port, high-speed can module
Hide thumbs Also See for NI 9853:
Table of Contents

Advertisement

specification says that significantly longer cable lengths may be
allowed at lower bit rates, but you should analyze each node for
signal integrity problems.

Number of CAN Nodes

The maximum number of nodes depends on the electrical
characteristics of the nodes on the network. If all nodes meet the
ISO 11898 requirements, you can connect at least 30 nodes to the
bus. You can connect higher numbers of nodes if the nodes'
electrical characteristics do not degrade signal quality below
ISO 11898 signal level specifications.
The NI 9853 electrical characteristics allow at least 110 CAN
ports on a network.

NI 9853 Hardware Overview

The NI 9853 has two full-featured, independent CAN ports that
are isolated from each other, and from the other modules in the
system. Each port or the NI 9853 has a Philips SJA1000
controller that is CAN 2.0B-compatible and fully supports both
11-bit and 29-bit identifiers. The port also has a Philips TJA 1041
14 | ni.com | NI 9853 Getting Started Guide