Takagi T-H3J-DV Service Handbook page 28

Condensing models
Table of Contents

Advertisement

HIGH ALTITUDE SETTINGS (CONTINUED)
WARNING
Failure to properly set the DIP switches could cause carbon monoxide poisoning, resulting in
severe personal injury or death.
Table 12: Indoor model, 540 (T-H3) - Propane
Apply the altitude setting by adjusting DIP switches 2, 3, and 4 on
the lower bank. See Figure 14.
0 to 2,000 ft.
2,000 to 3,000 ft.
3,000 to 5,000 ft.
5,000 to 7,500 ft.
7,500 to 10,100 ft.
Table 13: Indoor model, 540 (T-H3) - Natural Gas
Apply the altitude setting by adjusting DIP switches 2, 3, and 4 on the lower bank. See Figure 14.
0 to 2,000 ft.
2,000 to 3,000 ft.
3,000 to 5,000 ft.
5,000 to 7,500 ft.
7,500 to 10,100 ft.
* **These settings are not listed in the 240(T-H3J),340(T-H3S), and 540(T-H3) installation manual.
28
On-Demand Water Heater Service Handbook for 240, 340 & 540 Condensing Models
Elevation
0(DEFAULT)
Special function*
Elevation
0(DEFAULT)
Special function*
DIP switch settings
Level
No.2
No.3
OFF
OFF
1
OFF
ON
2*
ON
ON
3
OFF
OFF
4*
ON
OFF
5
OFF
ON
6
ON
ON
ON
OFF
DIP switch settings
Level
No.2
No.3
OFF
OFF
OFF
ON
1
ON
ON
2*
OFF
OFF
3
ON
OFF
4*
OFF
ON
5
ON
ON
6
ON
OFF
Figure 14
: 540 (T-H3)
Lower bank of
DIP switches
Fan motor
Output
speed
reduction
No.4
change
OFF
N/A
OFF
N/A
OFF
-8 %
ON
-11 %
ON
-14 %
ON
-18 %
ON
-22 %
OFF
N/A
Fan motor
Output
speed
reduction
No.4
change
OFF
N/A
OFF
N/A
OFF
-6 %
ON
-9 %
ON
-12 %
ON
-15 %
ON
-18 %
OFF
N/A
N/A
3 %
5 %
7 %
9 %
12 %
15 %
-7%
N/A
6%
10 %
14 %
18 %
22 %
26 %
-7 %

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-h3-dvT-h3s-osT-h3s-dvT-h3j-osT-h3-os100 series ... Show all