HIGH ALTITUDE SETTINGS (CONTINUED)
WARNING
Failure to properly set the DIP switches could cause carbon monoxide poisoning, resulting in
severe personal injury or death.
Table 12: Indoor model, 540 (T-H3) - Propane
Apply the altitude setting by adjusting DIP switches 2, 3, and 4 on
the lower bank. See Figure 14.
0 to 2,000 ft.
2,000 to 3,000 ft.
3,000 to 5,000 ft.
5,000 to 7,500 ft.
7,500 to 10,100 ft.
Table 13: Indoor model, 540 (T-H3) - Natural Gas
Apply the altitude setting by adjusting DIP switches 2, 3, and 4 on the lower bank. See Figure 14.
0 to 2,000 ft.
2,000 to 3,000 ft.
3,000 to 5,000 ft.
5,000 to 7,500 ft.
7,500 to 10,100 ft.
* **These settings are not listed in the 240(T-H3J),340(T-H3S), and 540(T-H3) installation manual.
28
•
On-Demand Water Heater Service Handbook for 240, 340 & 540 Condensing Models
Elevation
0(DEFAULT)
Special function*
Elevation
0(DEFAULT)
Special function*
DIP switch settings
Level
No.2
No.3
OFF
OFF
1
OFF
ON
2*
ON
ON
3
OFF
OFF
4*
ON
OFF
5
OFF
ON
6
ON
ON
ON
OFF
DIP switch settings
Level
No.2
No.3
OFF
OFF
OFF
ON
1
ON
ON
2*
OFF
OFF
3
ON
OFF
4*
OFF
ON
5
ON
ON
6
ON
OFF
Figure 14
: 540 (T-H3)
Lower bank of
DIP switches
Fan motor
Output
speed
reduction
No.4
change
OFF
N/A
OFF
N/A
OFF
-8 %
ON
-11 %
ON
-14 %
ON
-18 %
ON
-22 %
OFF
N/A
Fan motor
Output
speed
reduction
No.4
change
OFF
N/A
OFF
N/A
OFF
-6 %
ON
-9 %
ON
-12 %
ON
-15 %
ON
-18 %
OFF
N/A
N/A
3 %
5 %
7 %
9 %
12 %
15 %
-7%
N/A
6%
10 %
14 %
18 %
22 %
26 %
-7 %