Takagi T-H3J-DV Service Handbook page 27

Condensing models
Table of Contents

Advertisement

HIGH ALTITUDE SETTINGS (CONTINUED)
WARNING
Failure to properly set the DIP switches could cause carbon monoxide
poisoning, resulting in severe personal injury or death.
Table 10: Outdoor model, 240 (T-H3J) / 340 (T-H3S) - Propane
Apply the altitude setting by adjusting DIP switches 3, 4,
and 5 as described below.
Elevation
0 to 2,000 ft.
2,000 to 4,000 ft.
4,000 to 6,000 ft.
Table 11: Outdoor model, 240 (T-H3J) / 340 (T-H3S) - Natural Gas
Apply the altitude setting by adjusting DIP switches 3, 4, and 5 as described below.
Elevation
0 to 2,000 ft.
2,000 to 4,000 ft.
4,000 to 6,000 ft.
* If the abnormal sound problem persists even with "Level 3" setting, please contact our Technical Service Department for
advice.
**These settings are not listed in the 240(T-H3J),340(T-H3S), and 540(T-H3) installation manual.
On-Demand Water Heater Service Handbook for 240, 340 & 540 Condensing Models
Level
0 (DEFAULT)
1**
3*
Special function**
Level
0 (DEFAULT)
1**
3*
Special function**
Figure 13 : 240 (T-H3J) and 340 (T-H3S)
DIP switch settings
No.3
No.4
OFF
OFF
OFF
ON
2
OFF
OFF
ON
OFF
ON
OFF
DIP switch settings
No.3
No.4
OFF
OFF
OFF
ON
2
OFF
OFF
ON
OFF
ON
OFF
Bank of DIP Switches
Fan motor
Output
speed
reduction
No.5
change
OFF
N/A
N/A
OFF
N/A
3 %
ON
-11 %
7 %
ON
-14 %
9 %
OFF
N/A
-7 %
Fan motor
Output
speed
reduction
No.5
change
OFF
N/A
N/A
OFF
N/A
6 %
ON
-9 %
14 %
ON
-12 %
18 %
OFF
N/A
-7 %
27