Igniting the Side Burner

Using the E2i™ Electronic Ignition to
Ignite the Side Burner
If one or more of the main burners on your grill are
already lit and you would like to ignite the side burner,
skip to step 3. If none of the main burners are lit and
you are only using the side burner, start with step 1.
1) Check that the side burner control knob is in the
off
position. Check by pushing in and turning
knob clockwise (A). Also check that all main burner
control knobs are in the off
position.
Note: It is important that all burner control knobs are
in the off
position before turning on the LPG cylinder.
2) Turn gas supply on by turning cylinder valve
anti-clockwise or by moving regulator lever to the
on position depending on your regulator/cylinder
connection.
3) Open the side burner lid (B).
4) Push the side burner control knob in and slowly
turn it anti-clockwise toward the ignite
until you hear ticking (C). Once ticking starts, hold
the knob in that position for 1-2 seconds and then
slowly continue turning anti-clockwise. The burner
should ignite at the high
position.
5) Check that the side burner is lit. The side burner
flame may be difficult to see on a bright sunny day.
6) Once side burner is ignited, continue turning the
knob anti-clockwise until you reach the desired
position.
7) If the side burner does not ignite within 4 seconds,
turn side burner control knob to the off
and wait five minutes to allow the gas to clear
before attempting to light the burner again.
Should the side burner fail to ignite using the
electronic ignition, refer to the TROUBLESHOOTING
section. There you will find instructions on igniting the
side burner with a match to help determine the exact
problem.
To Extinguish Side Burner
1) Push side burner control knob in and then turn
clockwise all the way to the off
2) Turn gas supply off at the LPG cylinder.
WARNING: Open side burner lid during
m
ignition.
WARNING: Do not lean over side burner while
m
igniting or cooking.
WARNING: If ignition does not occur within
m
four seconds of attempting to light the side
burner, turn the burner control knob to
the off position. Wait five minutes to allow
accumulated gas to dissipate, and then repeat
the lighting procedure.
position
position
position.
Grilling
at Night
Using the Grill Light
To activate the grill light press the awake button.
The grill light has a tilt sensor that will turn on
the light if the grill lid is opened and turn off the
light when the grill lid is closed. If the lid is left
open or closed for more than 30 minutes, the
grill light will automatically deactivate. To turn
the light back on, press the awake button.
NOTE: The light does not turn off by pressing the
awake button.
Using the Lighted Control Knobs
The burner control knobs light up with the push
of a button. To turn on or off, simply push the
power button located on the right side of the
control panel.