W8735G Gateway Led Codes; Wiring The Auxiliary Input/Output Terminals - Honeywell W8735G Installation Instructions Manual

Communication gateway
Table of Contents

Advertisement

W8735G COMMUNICATION GATEWAY
CHANNEL TERMINAL
1 /D
2 /R
3 /B
Fig. 4. Communication Bus Terminals (4-channel).
Event
Battery good
Battery low
Battery dead
Time not available
Attempting to connect to
server
Connected to server
Server NACK
License expired
EnviraCOM
communication loss
Auxiliary alarm
Critical alarm
Wiring the Auxiliary Input/Output
Terminals
The Auxiliary contacts are available to integrate non-
EnviraCOM sensors and switches to the W8735G and to
allow the W8735G to interface with non-EnviraCOM
monitoring devices in case an alert condition is detected. See
Fig. 6 for AUX-IN and AUX-OUT wiring connections.
69-2432—01
M29957
Table 2. LED Diagnostic Blink Code.
Priority
LOWEST
Normal Operation.
Replace the battery.
No backup battery. Risk of data loss during power outage.
Gateway has not connected to the server yet.
Gateway is trying to contact the server, data transfer not
started yet.
Gateway is connected to server and data transfer is in
progress.
No account set up for the gateway on server.
One or more of the active channels have expired license.
One or more of the active channels have stopped working
(no data received for five minutes).
Power lost to the Auxiliary Input.
HIGHEST
One or more of the active channels have active critical
alarm, or a critical global alarm is active.
2
TO OPTIONAL
ENVIRACOM
CONTROLS
AND SENSORS
R7184U OIL
PRIMARY CONTROL
1
THERMOSTAT OPTIONAL.
2
REVIEW COMPONENTS AND ACCESSORIES SECTION FOR
COMPATIBLE DEVICES.
Fig. 5. W8735G with EnviraCOM oil primary and

W8735G GATEWAY LED CODES

The multipurpose LED is used to indicate battery life, gateway
functionality, and abnormal (alarm) conditions. In case of
multiple events, only the event with the highest priority will be
displayed.
Description
AUXILIARY INPUT (AUX-IN)
Generic devices such as flood sensors, temperature
controllers (for attic or outdoor temperature sensing) and
basic 24 Vac/Vdc thermostats can be connected to the
Auxiliary Input contacts to integrate non-EnviraCOM devices
to the W8735G.
4
VISIONPRO IAQ
1
W8735G
COMMUNICATION
1
2
3
GATEWAY
1/D
2/R
3/B
EnviraCOM™
Enabled
1
2
3
Status
POWER
TELEPHONE
NETWORK
VisionPRO IAQ.
LED Color Flashes
Green (Solid)
Green/Off
Green/Red
Red/Amber/Green
Amber/Green
Amber (Solid)
Amber/Red
Red (Solid)
Red/Off/Amber/Off
Amber/Off
Red/Off