  • Page 2 Dansk (oversat fra original brugsvejledning) Deutsch (übersetzt von den originalanweisungen) English (original instructions) Español (traducido de las instrucciones originales) Français (traduction de la notice d’instructions originale) Italiano (tradotto dalle istruzioni originali) Nederlands (vertaald vanuit de originele instructies) Norsk (oversatt fra de originale instruksjonene) Português (traduzido das instruções originais) Suomi (käännetty alkuperäisestä...
  • Page 3 Fig. A Fig. B Fig. C Fig. E Fig. D...
  • Page 4 Fig. F Fig. G Fig. H Fig. I Fig. K Fig. J...
  • Page 5 Fig. L...
  • Page 6: Technical Data

    English HEAVY-DUTY CONSTRUCTION DUST EXTRACTOR DWV902L, DWV902M, DWV902MT Congratulations! You have chosen a D WALT tool. Years of experience, thorough product development and innovation make D WALT one of the most reliable partners for professional power tool users. Technical Data DWV902L QS/GB...
  • Page 7: Important Safety Instructions

    English DANGER: Indicates an imminently hazardous • Do not put any objects into the openings of the appliance. Do situation which, if not avoided, will result in death or not use the appliance with any opening blocked; keep free of serious injury.
  • Page 8: Using An Extension Cable

    Do not switch on until the complete filter system has been installed. DWV902l This appliance can be used as industrial vacuum cleaner and dust extractor for mobile operations to take up all types of dry, non-combustible dusts up to dust Class L with limit values for occupational exposure greater than 1 mg/m³.
  • Page 9 Children should never be left alone with this product. Flow Alarm Adjustment (Fig. D) Anti-Static Hose Option Class M models only The DWV902L, DWV902M and DWV902MT are each equipped Adjust the flow alarm adjustment control  to the correct  16  with an anti-static grounding system. An anti-static hose must hose (or tube) inside diameter size or accessory diameter be purchased at extra cost from your authorised service center.
  • Page 10: Automatic Filter Cleaning System

    English adapter (available from your local D WALT supplier). Refer CAUTION: Clean the water level limiting device regularly to the Accessories section for detail on available adapters. and examine it for signs of damage. nOTE: If using an adapter ensure it is firmly attached to the NOTICE: DO NOT remove ball float ...
  • Page 11: Filter Care

    English WARNING: For user servicing, the machine must be 5. Inspect filters for wear, tears or other damage. dismantled, cleaned and serviced, as far as is reasonably nOTE: If there is any doubt on the condition of the filters practicable, without causing risk to the maintenance staff they MUST be replaced.
  • Page 12: Protecting The Environment

    English Optional Accessories Troubleshooting WARNING: Since accessories, other than those offered by Problem Solution WALT, have not been tested with this product, use of Motor does Check power cord, plugs and outlet. such accessories with this appliance could be hazardous. not run To reduce the risk of injury, only D WALT recommended...