TH-103PF12E
10.1.3. P.C.B. (Print Circuit Board) and Plasma Display Panel exchange
10.1.3.1. Quick adjustment after P.C.B. and Panel exchange
1. To remove P.C.B., wait 10 minute after power was off for discharge from electrolysis capacitors.
10.1.3.2. Quick adjustment after P.C.B. exchange
Adjust the following voltages with the multimeter.
P.C.B.
P Board (Main_1)
Vsus
Vda
P Board (Main_2)
Vsus
Vda
SC Board
Vad
Vscn
SS Board
Ve**
D, DS Board
White balance and Sub brightness for NTSC, PAL, HD, PC and 625i signals
DN Board
Set Market Select Number to correct destination by MS mode. (See chap. 6.1.5)
D, DN Board
Set Ve Mode until bright points disappears by IIC mode.
*See the Panel Label.
**See chap. 10.1.6.
***See chap. 10.1.7.1.
10.1.3.3. Quick adjustment after Plasma Display Panel exchange
Adjust the following voltages with the multimeter.
Name
Vsus (SC Side)
Vsus(SS Side)
Ve Life
*See the Panel Label.
10.1.4. Vsus adjustment
After exchange P board or Plasma Display Panel, see the Panel Label and check TPVSUS and adjust the volume.
10.1.5. Vad adjustment
After exchange SC board, check TP9 and adjust the volume.
10.1.6. Ve adjustment
1. After exchange SS board, connect the multimeter to the testpoint TPVE(SS).
2. Select Ve Mode by IIC mode. (See chap. 6.1.1., and 6.2.)
Name
Test Point
TPVSUS (SC)
TP9 (P_Main_1)
TPVSUS (SS)
TP9 (P_Main_2)
TPVAD (SC)
TPVSCN (SC)
TPVE (SS)
Test Point
TPVSUS (SC)
Vsus ± 2V
TPVSUS (SS)
Vsus ± 2V
Check Ve Mode. (See chap. 10.1.7.2.)
Voltage
Vsus ± 2V
VR251 (P_Main_1)
70V +1V, -2V
Fixed
Vsus ± 2V
VR251 (P_Main_2)
70V +1V, -2V
Fixed
-135V ± 1V
VR16600 (SC)
Vad_base:+145V±4V
Fixed
GND_base: +10V±6V
Ve ± 1V
VR16001 (SS)
Voltage
Volume
VR251 (P_Main_1)
VR251 (P_Main_2)