Replacing the Line Fuse

Tools Required

• small slot screwdriver

Removal

WARNING
For continued protection against fire hazard, replace fuse only with
same type and rating (3 A 250 V F). The use of other fuses or
materials is prohibited.
1. Disconnect the power cord.
2. Use a small slot screwdriver to pry open the fuse holder.
3. Replace the blown fuse. For 115V operation, use a 5A 125V TD fuse (HP part number
2110-1059). For 230V operation, use a 4A 250V TD fuse (HP part number 2110-0734).

Replacement

1. Replace the fuse holder.