Minimum Clearances To Combustible Material - J. A. Roby CUISINIERE Instruction Manual

Hide thumbs Also See for CUISINIERE:
Table of Contents

Advertisement

Minimum clearances to combustible material

This appliance needs a minimum space because of these reduced clearances. Whether in the living room or the dining room, the
CUISINIERE cook stove will match perfectly by its originality and heating. It requires a MINIMUM clearance of 12 inches at the back
(for a single pipe with a heat shield) and an 18 inch MINIMUM clearance on each side.
In case of a single pipe without heat shield, you must keep CUISINIERE cook stove 18 inches away from all
combustible material so that the MINIMUM clearance at the back of the stove will be 16¼ inches (41.3cm).
For a 45° corner installation, or other corner installation, the
minimum clearance between the cook stove and combustible
material must be 18 inches.
November 5, 2015
8

Hide quick links:

Advertisement

Table of Contents
loading