Installation

Floor protection

Your stove must be installed on a plate of non-combustible material to protect the floor and avoid fire caused by:
Projections of sparks at the moment of opening the door and loading;
The heat radiation of runaway which might cause self-ignition of floor and surface;
Possible creosote flow when there is a chimney fire.
UNITED STATES ONLY: The surface must be non-combustible and listed to the USA standard UL1618 or the local codes (Example:
cement, brick, ceramic tiles etc.)

Minimum dimension of floor protection plate

The following dimensions are the minimum values.
Canada:
 49 7/8 in (126.6 cm)
 66 3/8 in (168.6 cm)
 3/8 in thickness (1 cm)
USA:
 47 7/8 in (121.6 cm)
 66 3/8 in (168.6 cm)
 3/8 in thickness (1 cm)
UNITED STATES ONLY: It's necessary to protect the floor beneath the horizontal part of chimney connector extending 2 inch (5cm)
beyond each side of the pipe. You can extend the floor protection panel while respecting the clearances of each side of stove.