Advertisement

Quick Links

PLEASE READ CAREFULLY AND KEEP
THIS MANUAL FOR FUTURE REFERENCE
Instruction Manual
ROBY2500
ROBY2500 CUISINIERE LX
ROBY2500 CUISINIERE
Tested and listed
ULC STD S627-00
UL 1482-7
CAN/CSA STD B415.1-10
490, rue de l'Argon
Quebec, CANADA G2N 2C9
Tel.: 418-849-8095
Fax : 418-849-0077
www.jaroby.com
November 5, 2015
Printed in Canada

Advertisement

Table of Contents
loading

Summary of Contents for J. A. Roby ROBY2500

  • Page 1 PLEASE READ CAREFULLY AND KEEP THIS MANUAL FOR FUTURE REFERENCE Instruction Manual ROBY2500 ROBY2500 CUISINIERE LX ROBY2500 CUISINIERE Tested and listed ULC STD S627-00 UL 1482-7 CAN/CSA STD B415.1-10 490, rue de l'Argon Quebec, CANADA G2N 2C9 Tel.: 418-849-8095 Fax : 418-849-0077 www.jaroby.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction ................3 Stainless steel tubes Installation ........24 Rating plate ................4 Operating Instructions ............25 Appliance Dimensions .............. 5 Control of primary and secondary air admission ....25 Installation ................6 Lightning fire ..............25 Floor protection ..............
  • Page 3: Introduction

    Introduction Read all instructions carefully before installing your new J. A. ROBY ROBY2500/ROBY2500 CUISINIERE wood stove. A proper installation is very important for a safe and effective use of your stove. If you have any doubts about the installation of your appliance correctly, we suggest to call a professional installer.
  • Page 4: Rating Plate

    Rating plate November 5, 2015...
  • Page 5: Appliance Dimensions

    Appliance Dimensions Figure 1 November 5, 2015...
  • Page 6: Installation

    Installation Floor protection Your stove must be installed on a plate of non-combustible material to protect the floor and avoid fire caused by: • Projections of sparks at the moment of opening the door and loading. • The heat radiation of runaway which might cause self-ignition of floor and surface. •...
  • Page 7: Clearances Chart On Floor Plate

    Clearances chart on floor plate The following dimensions are the minimum values. Canada: • 8 inches (20.32 cm) rear • 8 inches (20.32 cm) side • 18 inches (45.72 cm) loading door Unites States: • 8 inches (20.32 cm) rear •...
  • Page 8: Minimums Clearances To Combustible Material

    This appliance needs a minimum space because of these reduced clearances. Whether in the living room or the dining room, the ROBY2500/ ROBY2500 CUISINIERE will match perfectly by its originality and heating. It requires a MINIMUM clearance of 12 inches at the back (for a single pipe with a heat shield) and an 18 inch MINIMUM clearance on each side.
  • Page 9: Assembly Before Installation

    Assembly before installation Warmer stove Assembly (Optional) The stove leg and the warming oven top might not be assembled At this moment, you need to know which type of smoke pipe you in the factory, in order to save space for transportation and are installing: a single pipe or a double pipe.
  • Page 10 Place the backside on the product package to protect Insert the chrome decoration in the holes and fix it the painted part. with carriage bolts and nuts (with 2 bolts each). Fix the left side. Attach the top part to the back and the front. Fix the right side.
  • Page 11: Fan And Snap Disc Box Installation

    Put and fix the warmer with the 6 holes at the back of Fan and Snap disc box installation the cook stove. Install the two fans at the bottom of vent box as illustrated. Please note that the cords must be placed as shown. Grid Screw the snap disc box into the holes made for this purpose at the back side near the vent box.
  • Page 12: Firebricks Installation

    Firebricks installation Back firebricks installation Side firebricks installation Put 4 bricks «A» and 1 brick «C» in the middle. Put 2 bricks «A» and 1 angled brick «E» on the right hand. Place 2 screws and insert split washers. Set the 3 big screws in the holes for this purpose. Do not tighten up these screws too much, so that washers will be easily installed.
  • Page 13 Floor firebricks installation Put 2 bricks «A» in the bottom as shown in the picture. Insert 4 bricks «A» in front of the 2 bricks previously placed. Insert 1 brick «A» to the right from the ash dump plug. Insert 1 brick «D» to the left from the ash dump plug. November 5, 2015...
  • Page 14 Firebricks installation on the pipes Put the rockwool over the bricks and assume then the The firebricks must be placed on the 4 pipes from the bottom of smoke exit way is not obstructed. combustion chamber. Bricks keep a maximum heat inside the combustion chamber so that the air coming from the pipes could burn the entire gas coming out from wood, which is combustible only in this way.
  • Page 15: General Stove Installation Steps

    General stove installation steps Mark the dimensions of protection panel on the floor. Read the entire installation manual before installing The edge clearance of the sides and the back is and using your stove. 8 inches (20.3 cm). At the front, it must be 16 inches (40.6 cm) in US and 18 inches (45 cm) in Canada, Choose a place to install your cook stove.
  • Page 16: Chimney Connector Installation

    1 inch (25.4 mm) thick. Double wall chimney connector ATTENTION: Your J.A. Roby ROBY2500/ ROBY2500 CUISINIERE cook stove was approved for the use of a single wall chimney • If you don’t have heat shield, you must keep the...
  • Page 17 Insert entirely the roll formed end into the stove collar and screwing it with a minimum of 3 screws. WARNING: It is mandatory to screw the pipe to the stove collar and also at each joints with a minimum of 3 screws.
  • Page 18: Mobile Home Installation

    Mobile home installation DANGER: DO NOT INSTALL IN BEDROOM. If the chimney is exposed outside from a wall WARNING: THE STRUCTURAL INTEGRITY OF THE and placed lower than 7 feet (213 cm) above MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST the ground level where the mobile home is situated.
  • Page 19: General Steps Of Chimney Installation

    Install fireguard in each level. The chimneys must be tested according to CAN/ULC-S629-M87 in Canada and to UL-103 (type HT) In USA. The ROBY2500/ Frame the hole into the roof. ROBY2500 CUISINIERE can be installed with a masonry chimney according to ULC-S635, ULC-S640 and UL-1777.
  • Page 20: Vertical Installation Inside Masonry Chimney

    The wood appliance must be installed in accordance with the applicable local laws or the CAN/CSA-B365, NFPA211 (USA) The ROBY2500/ROBY2500 CUISINIERE must be installed in norms. Follow the chimney manufacturer’s instructions to install accordance with the applicable local laws or the standards such the chimney.
  • Page 21: Vertical Installation On Cathedral Roof

    Vertical Installation on Cathedral Roof Offset Vertical Installation The ROBY2500/ROBY2500 CUISINIERE must be installed in The ROBY2500/ROBY2500 CUISINIERE cook stove must be accordance with the applicable local laws or the CAN/CSA- installed in accordance with the applicable local laws or the B365, NFPA 211 (USA).
  • Page 22: Vertical Installation

    Vertical Installation The ROBY2500/ROBY2500 CUISINIERE must be installed in accordance with the applicable local laws or the CAN/CSA- B365, NFPA 211 (USA). Follow the chimney manufacturer’s instructions to install the chimney. Combustion air intake Air Inlet Obstruction In conventional designed homes, natural ventilation is enough to operate the wood stove efficiently.
  • Page 23: Replacing Stainless Steel Deflector

    Replacing stainless steel deflector Your stove has an inside deflector of stainless steel to prevent Replacing Front deflector premature wear of another steel deflector below. Being The stainless steel plate at front is installed to protect the exposed to extreme heat, as time goes by, this stainless steel passage of primal air intake.
  • Page 24: Replacement Stainless Steel Tubes

    Replacement stainless steel tubes Although the tubes are made of stainless steel, with extreme Align and insert the notched end into the other hole. temperature and conditions the tubes are eventually corroded and perforated as normal deterioration. They must be replaced by new ones to ensure performance of your stove.
  • Page 25: Operating Instructions

    Operating Instructions Control of primary and secondary air First fire admission For the first hours of operation, you must heat your appliance gradually. In order to allow an appropriate baking of the paint When the handle on the left side of the stove is vertical, the air and to facilitate its adhesion with metal, do not heat the admission is only from the tube.
  • Page 26: Maintenance

    Maintenance Ash Removal Ash Disposal The ash has to be removed periodically every 2 or 3 days Some embers are mixed with ash and can remain lit. If embers during heavy warming period. Never leave excessive have enough oxygen, it can stay lit some hours and even some accumulation into the combustion chamber because it can few days.
  • Page 27: Chimney Sweeping

    Chimney Sweeping Cleaning up glass Chimney Sweeping needs special tools like some glass fiber To clean the door glass, J.A. Roby Inc. recommends using products for this purpose or an oven cleaner only for glass part. rods and a suitable brush to the chimney’s diameter. •...
  • Page 28: Replacing Glass Fiber Rope

    Replacing glass fiber rope What to do in case of Chimney When the braided glass fibre rope is all flattened out, it Fire becomes impossible to close the door hermetically. This means that the glass fibre rope is no longer usable or that the Contact your local authority to know what to do in case of rope is damaged.
  • Page 29: Annexe 1

    Annexe 1 Door assembly Wood Stove Door *The same assembly for an arc wood stove. November 5, 2015...
  • Page 30: Annexe 2

    Annexe 2 Replacement parts • Bricks • Stove ceramic glass • Spring handle • Stove door • Fans • Flat fiber glass rope (around glass) • Round fiberglass rope • Ash plug • Slotted brick washer Call your sales representative to order these parts. November 5, 2015...
  • Page 31: J. A. Roby Limited Lifetime Warranty

    STOVES & FIREPLACES J. A. Roby Limited Lifetime warranty WOOD BURNING STOVES & FIREPLACES J. A. ROBY’s warranty only applies to original buyer and is non-transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from factory. The products covered by this warranty must be manufactured after the review date indicated at the bottom of page.

This manual is also suitable for:

Roby2500 cuisiniere lx

Table of Contents