Pioneer PDP-5000EX Service Manual page 161

Hide thumbs Also See for PDP-5000EX:
Table of Contents

Advertisement

5
Subcategory of NG
=> 1: Data on Subcategories for failure in 3-wire serial communication of Main microcomputer
Data
2
Multi processor main communication failure (MULIT1)
4
Multi processor communication failure (I/P)
6
Multi processor sub communication failure (SLAVE)
7
Main communication failure (FPGA1)
8
Multi processor communication failure (FPGA2)
Subcategory of NG
=> 2: Data on Subcategories for failure in IIC communication of Main microcomputer
Data
0
Non subcategory
4
AV Switch
5
RGB Switch
8
Main VDEC
9
Sub VDEC
A
AD/PLL
B
HDMI
G
64K EEPROM
H
AUDIO IC
K
DVI Receiver
L
AUDIO Switch
M
VOLUME IC
Subcategory of NG
=> 3: Data on Subcategories for failure in the ASIC power (POWER)
Data
1
DCDC converter reduce voltage (M-DCDC)
2
Relay power reduce voltage (RELAY)
5
6
Cause of Shutdown
Cause of Shutdown
Cause of Shutdown
PDP-5000EX
6
7
Remarks
Remarks
Remarks
7
8
A
B
C
D
E
F
161
8