Pioneer PDP-5000EX Service Manual page 125

Hide thumbs Also See for PDP-5000EX:
Table of Contents

Advertisement

5
8.2.1.3 TEMPERATURE
The current temperature and fan rotation state are displayed.
1
1
5
10
15
16
1
1
5
10
15
16
• Display
Temperature indications
TEMP1: The temperature of the sensor in the panel is indicated in Celsius (models for Japan and Europe) or in Fahrenheit (models
for North America).
TEMP2: The A/D input value at Pin 76 (AN0) of the main microcomputer is converted to the temperature value and indicated in
Celsius (models for Japan and Europe) or in Fahrenheit (models for North America). The 10-bit A/D value is also indicated.
(Note: A shutdown process starts when the sensor temperature exceeds the specified maximum [C].)
Fan output indication
One of the following indications is displayed:
STOP
: The fan stops.
LOW
: The fan rotates at a low speed.
MIDDLE : The fan rotates at a medium speed.
HIGH
: The fan rotates at a high speed.
Note: According to where and how the unit is installed, there may be a difference between the measured sensor temperature and the
ambient temperature. Also, the quality of the sensor varies within tolerable limits from product to product.
So use the sensor temperature only as a guide.
Note: Press the [»] and [«] keys to update the temperature because the sensor temperature is not automatically updated.
5
6
5
10
15
20
I
N
F O R
M
A
T I O
N
V
D 1
T
E
M P
E
R
A
T
U R E
T
E
M
P 1
:
+
0
5
. 2
T
E
M
P 2
:
+
4
0
. 2
:
F
A
N
S
T
O P
Screen: TEMPERATURE (For Japan and Europe)
5
10
15
20
I
N
F O R
M
A
T I O
N
V
D 1
T
E
M P
E
R
A
T
U R E
T
E
M
P 1
:
0
4
1
. 0
T
E
M
P 2
:
1
0
4
. 3
:
F
A
N
S
T
O P
Screen: TEMPERATURE (For North America)
PDP-5000EX
6
7
25
30
35
3
0 6 0
1
– N T V
J
W
M 7
( C )
( C )
1
3
0
( A / D )
25
30
35
3
0 6 0
1
– N T V
A
W
M 7
( F )
( F )
1
3
0
( A / D )
7
8
40
40
8
A
B
C
D
E
F
125

Hide quick links:

Advertisement